Controlled Clinical Trial
. 2016 Nov;47(2):133-142.
doi: 10.1007/s10840-016-0138-1. Epub 2016 May 18.

Outcomes after cryoballoon or radiofrequency ablation for persistent atrial fibrillation: a multicentric propensity-score matched study

Affiliations
Controlled Clinical Trial

Outcomes after cryoballoon or radiofrequency ablation for persistent atrial fibrillation: a multicentric propensity-score matched study

Serge Boveda et al. J Interv Card Electrophysiol. 2016 Nov.

Abstract

Purpose: Recent data show no benefit of additional ablation beyond pulmonary vein isolation (PVI) in persistent atrial fibrillation (AF). Evidence suggests that radiofrequency energy (RF) and cryoballoon (CRYO) have comparable efficacy for PVI. We aimed to assess the outcomes after a single catheter ablation procedure, comparing PVI using CRYO vs. RF ablation for PVI plus additional ablation in a cohort of patients with persistent AF.

Methods: In this prospective multicenter propensity score-matched comparison, 59 consecutive patients undergoing CRYO ablation of persistent AF were matched to 59 patients treated with RF from November 2010 to June 2012.

Results: During a mean follow-up of 15.6 ± 11.5 months, 43.2 % of patients presented atrial arrhythmia relapse after a blanking period of 3 months, which was comparable between the two groups (40.7 % in CRYO vs. 45.8 % in RF, Log rank P = 0.14; HR = 0.67, 95 %CI 0.38-1.16, P = 0.15), despite the fact that 52.5 % of RF patients add additional complex fractionated atrial electrogram ablation, as well as left atrial linear ablation in over two-thirds (roof line in 67.8 % and mitral isthmus in 32.2 %). On multivariate Cox regression, only AF duration in years (HR = 1.10, 95 %CI 1.01-1.10, P = 0.04) was a predictor of relapse. Patients undergoing RF ablation presented a numerically, but non-significantly, lower complication rate (6.8 vs 10.2 %, P = 0.51).

Conclusion: In our multicenter experience, freedom from atrial arrhythmias was comparable among matched patients treated with CRYO and RF, despite non-significant trends in favor of RF in terms of complications, at the cost of longer procedure times.

Keywords: Arrhythmia relapse; Atrial fibrillation; Cryoballoon ablation; Pulmonary vein isolation; Radiofrequency ablation.

PubMed Disclaimer

References

    1. Circ Arrhythm Electrophysiol. 2012 Oct;5(5):957-67 - PubMed
    1. Europace. 2015 Apr;17(4):559-65 - PubMed
    1. Circ Arrhythm Electrophysiol. 2015 Apr;8(2):308-17 - PubMed
    1. J Am Coll Cardiol. 2009 Mar 3;53(9):782-9 - PubMed
    1. Circ Arrhythm Electrophysiol. 2012 Apr;5(2):287-94 - PubMed