Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 Jul;79(7):637-45.
doi: 10.1002/jemt.22677. Epub 2016 May 19.

Comparative B-mode and Doppler renal ultrasonography with histopathological findings in dogs positive for canine visceral leishmaniasis

Affiliations

Comparative B-mode and Doppler renal ultrasonography with histopathological findings in dogs positive for canine visceral leishmaniasis

Pollyana Irene Baltazar et al. Microsc Res Tech. 2016 Jul.

Abstract

Morphological parameters and renal flow were assessed and measured in six clinically healthy dogs with negative serological and parasitological examinations for canine visceral leishmaniasis (CVL) and six dogs with CVL-positive serological and parasitological tests and asymptomatic condition of the disease. Kidney length and diameter were measured and compared with the aorta/kidney ratio. Alterations in flow were measured using the flow velocity (cm/s) and resistance index (RI). Renal function was assessed by serum biochemical examination (urea, creatine, total proteins, albumin, and globulin) and urinalysis. CVL-positive animals presented heterogeneous kidney echotexture, reduced vascular flow, hypoperfusion, lesser visualization of the arcuate arteries, high RI values (1.06 ± 0.28 for the right kidney and 1.10 ± 0.30 for the left kidney), reduced diastolic flow, and high systolic peak. They also presented positive creatine/RI correlation and between the renal artery vascular flow and kidney diameter. Histopathological analysis of CVL-positive animals was compatible and confirmed hemodynamic changes observed by Doppler ultrasound. The findings in the present study showed that Doppler ultrasonography is a valid method to assess and detect alterations in flow in renal pathological processes with kidney vascular damage, as in the case of leishmaniasis, and can help in the diagnosis of animals with this infection. Microsc. Res. Tech. 79:637-645, 2016. © 2016 Wiley Periodicals, Inc.

Keywords: CVL; renal failure; renal ultrasound.

PubMed Disclaimer

LinkOut - more resources