Ambient ionization mass spectrometric analysis of human surgical specimens to distinguish renal cell carcinoma from healthy renal tissue
- PMID: 27206411
- PMCID: PMC4939286
- DOI: 10.1007/s00216-016-9627-4
Ambient ionization mass spectrometric analysis of human surgical specimens to distinguish renal cell carcinoma from healthy renal tissue
Abstract
Touch spray-mass spectrometry (TS-MS) is an ambient ionization technique (ionization of unprocessed samples in the open air) that may find intraoperative applications in quickly identifying the disease state of cancerous tissues and in defining surgical margins. In this study, TS-MS was performed on fresh kidney tissue (∼1-5 cm(3)), within 1 h of resection, from 21 human subjects afflicted by renal cell carcinoma (RCC). The preliminary diagnostic value of TS-MS data taken from freshly resected tissue was evaluated. Principal component analysis (PCA) of the negative ion mode (m/z 700-1000) data provided the separation between RCC (16 samples) and healthy renal tissue (13 samples). Linear discriminant analysis (LDA) on the PCA-compressed data estimated sensitivity (true positive rate) and specificity (true negative rate) of 98 and 95 %, respectively, based on histopathological evaluation. The results indicate that TS-MS might provide rapid diagnostic information in spite of the complexity of unprocessed kidney tissue and the presence of interferences such as urine and blood. Desorption electrospray ionization-MS imaging (DESI-MSI) in the negative ionization mode was performed on the tissue specimens after TS-MS analysis as a reference method. The DESI imaging experiments provided phospholipid profiles (m/z 700-1000) that also separated RCC and healthy tissue in the PCA space, with PCA-LDA sensitivity and specificity of 100 and 89 %, respectively. The TS and DESI loading plots indicated that different ions contributed most to the separation of RCC from healthy renal tissue (m/z 794 [PC 34:1 + Cl](-) and 844 [PC 38:4 + Cl](-) for TS vs. m/z 788 [PS 36:1 - H](-) and 810 [PS 38:4 - H](-) for DESI), while m/z 885 ([PI 38:4 - H](-)) was important in both TS and DESI. The prospect, remaining hurdles, and future work required for translating TS-MS into a method of intraoperative tissue diagnosis are discussed. Graphical abstract Touch spray-mass spectrometry used for lipid profiling of fresh human renal cell carcinoma. Left) Photograph of the touch spray probe pointed at the MS inlet. Right) Average mass spectra of healthy renal tissue (blue) and RCC (red).
Keywords: Cancer; Desorption electrospray ionization; Mass spectrometry; Multivariate statistics; Surgical tissue analysis; Touch spray ionization.
Conflict of interest statement
The authors declare that they have no conflict of interest.
Figures


Similar articles
-
MALDI Orbitrap Mass Spectrometry Profiling of Dysregulated Sulfoglycosphingolipids in Renal Cell Carcinoma Tissues.J Am Soc Mass Spectrom. 2017 Aug;28(8):1562-1574. doi: 10.1007/s13361-017-1644-9. Epub 2017 Mar 30. J Am Soc Mass Spectrom. 2017. PMID: 28361385
-
Differentiation of prostate cancer from normal tissue in radical prostatectomy specimens by desorption electrospray ionization and touch spray ionization mass spectrometry.Analyst. 2015 Feb 21;140(4):1090-8. doi: 10.1039/c4an02039a. Analyst. 2015. PMID: 25521825 Free PMC article.
-
Analysis of colorectal adenocarcinoma tissue by desorption electrospray ionization mass spectrometric imaging.Anal Bioanal Chem. 2012 Jun;403(8):2315-25. doi: 10.1007/s00216-012-5841-x. Epub 2012 Mar 25. Anal Bioanal Chem. 2012. PMID: 22447214
-
Surface analysis of lipids by mass spectrometry: more than just imaging.Prog Lipid Res. 2013 Oct;52(4):329-53. doi: 10.1016/j.plipres.2013.04.005. Epub 2013 Apr 24. Prog Lipid Res. 2013. PMID: 23623802 Review.
-
Ambient Mass Spectrometry in Cancer Research.Adv Cancer Res. 2017;134:231-256. doi: 10.1016/bs.acr.2016.11.011. Epub 2016 Dec 29. Adv Cancer Res. 2017. PMID: 28110652 Review.
Cited by
-
Integration of Ion Mobility MSE after Fully Automated, Online, High-Resolution Liquid Extraction Surface Analysis Micro-Liquid Chromatography.Anal Chem. 2017 Oct 17;89(20):11143-11150. doi: 10.1021/acs.analchem.7b03512. Epub 2017 Oct 6. Anal Chem. 2017. PMID: 28945354 Free PMC article.
-
Laser Ablation Remote-Electrospray Ionisation Mass Spectrometry (LARESI MSI) Imaging-New Method for Detection and Spatial Localization of Metabolites and Mycotoxins Produced by Moulds.Toxins (Basel). 2020 Nov 18;12(11):720. doi: 10.3390/toxins12110720. Toxins (Basel). 2020. PMID: 33217921 Free PMC article.
-
Ambient ionization mass spectrometry imaging for disease diagnosis: Excitements and challenges.J Biosci. 2018 Sep;43(4):731-738. J Biosci. 2018. PMID: 30207318 Review.
-
Direct sampling mass spectrometry for clinical analysis.Analyst. 2019 Feb 11;144(4):1034-1051. doi: 10.1039/c8an01722k. Analyst. 2019. PMID: 30520890 Free PMC article. Review.
-
Localization of Metabolites of Human Kidney Tissue with Infrared Laser-Based Selected Reaction Monitoring Mass Spectrometry Imaging and Silver-109 Nanoparticle-Based Surface Assisted Laser Desorption/Ionization Mass Spectrometry Imaging.Anal Chem. 2020 Mar 17;92(6):4251-4258. doi: 10.1021/acs.analchem.9b04580. Epub 2020 Feb 28. Anal Chem. 2020. PMID: 32083846 Free PMC article.
References
-
- Howlader NNA, Krapcho M, Garshell J, Miller D, Altekruse SF, Kosary CL, Yu M, Ruhl J, Tatalovich Z, Mariotto A, Lewis DR, Chen HS, Feuer EJ, Cronin KA. SEER Cancer Statistics Review, 1975–2012. National Cancer Institute; 2015.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials
Miscellaneous