Effect of Different Surface Treatments and Thermocycling on Bond Strength of a Silicone-based Denture Liner to a Denture Base Resin
- PMID: 27207005
- DOI: 10.5005/jp-journals-10024-1819
Effect of Different Surface Treatments and Thermocycling on Bond Strength of a Silicone-based Denture Liner to a Denture Base Resin
Abstract
Aim: The aim of this study is to evaluate the effects of three different surface treatments and thermocycling on the tensile strength of a silicone lining material to denture resin.
Materials and methods: A total of 96 cube-shaped specimens were fabricated using heat-cured polymethyl methacrylate (PMMA) denture base resin. Three millimeters of the material was cut from the midsection. The specimens were divided into four groups. The bonding surfaces of the specimens in each group received one of the following surface treatments: no surface treatment (control group), airborne particle abrasion with 110 pirn alumina particles (air abrasion group), Er:yttrium aluminum garnet laser irradiation (laser group), and air abrasion + laser. After the lining materials were processed between the two PMMA blocks, each group was divided into two subgroups (n = 12), either stored in distilled water at 37°C for 24 hours or thermocycled between 5 and 55°C for 5,000 cycles. The specimens were tested in tensile and shear strength in a universal testing machine. Data were analyzed with two-way analysis of variance and Tamhane's post hoc tests (α = 0.05). The mode of failure was determined, and one specimen in each group was examined by scanning electron microscopy.
Results: Surface-treated groups demonstrated significantly higher tensile strengths compared to the control group (p < 0.001). Nonetheless, no significant differences were found between surface-treated groups (p > 0.05). The tensile strength was significantly different between thermocycled and water-stored specimens (p = 0.021).
Conclusion: Altering the surface of the acrylic denture base resin with air abrasion, laser, and air abrasion + laser increased the tensile strength. Thermocycling resulted in decrease in bond strength of silicone-based liner to surface-treated acrylic resin.
Clinical significance: Pretreatment of denture base resins before applying the soft liner materials improves the bond strength. However, thermocycling results in decrease in bond strength of soft denture liner to surface-treated acrylic resin.
Keywords: Bond strength; Er:YAG laser; Resilient denture liner; Thermocycling..
Similar articles
-
Effect of surface treatments on the bond strength of soft denture lining materials to an acrylic resin denture base.J Prosthet Dent. 2014 Oct;112(4):964-71. doi: 10.1016/j.prosdent.2014.01.017. Epub 2014 Apr 14. J Prosthet Dent. 2014. PMID: 24726594
-
Effect of thermocycling on tensile bond strength of six silicone-based, resilient denture liners.J Prosthet Dent. 2003 Mar;89(3):303-10. doi: 10.1067/mpr.2003.41. J Prosthet Dent. 2003. PMID: 12644808
-
Effect of storage duration on the hardness and tensile bond strength of silicone- and acrylic resin-based resilient denture liners to a processed denture base acrylic resin.J Prosthet Dent. 2008 Feb;99(2):153-9. doi: 10.1016/S0022-3913(08)60032-3. J Prosthet Dent. 2008. PMID: 18262017
-
Bond strength of soft liners to denture base resins and the influence of different surface treatments and thermocycling: A systematic review.J Prosthet Dent. 2020 Jun;123(6):800-806.e6. doi: 10.1016/j.prosdent.2019.06.013. Epub 2019 Nov 5. J Prosthet Dent. 2020. PMID: 31703921
-
Application of Laser Treatment in Adhesive Bonding of Liners to Polymethyl Methacrylate Denture Resins: A Systematic Review and Meta-Analysis.Photobiomodul Photomed Laser Surg. 2023 Nov;41(11):608-621. doi: 10.1089/photob.2023.0066. Epub 2023 Oct 31. Photobiomodul Photomed Laser Surg. 2023. PMID: 37910776
Cited by
-
Effect of Er:YAG laser radiation on pull-out fracture load of esthetic posts luted to root canal dentin with various resin cements.Dent Res J (Isfahan). 2021 Mar 17;18:17. eCollection 2021. Dent Res J (Isfahan). 2021. PMID: 34104364 Free PMC article.
-
Soft Denture Liner Adhesion to Conventional and CAD/CAM Processed Poly(Methyl Methacrylate) Acrylic Denture Resins-An In-Vitro Study.Materials (Basel). 2021 Nov 3;14(21):6614. doi: 10.3390/ma14216614. Materials (Basel). 2021. PMID: 34772140 Free PMC article.
-
Effect of Ozone and Two Common Denture Cleaners on Tensile Bond Strength and Surface Hardness of a Silicone Soft Liner.Front Dent. 2019 Sep-Oct;16(5):351-356. doi: 10.18502/fid.v16i5.2280. Epub 2019 Oct 15. Front Dent. 2019. PMID: 32123875 Free PMC article.
-
Comparative Evaluation of Hardness and Energy Absorption of Some Commercially Available Chairside Silicone-Based Soft Denture Liners and a Heat-Cured Soft Denture Liner.Clin Cosmet Investig Dent. 2023 Oct 4;15:205-213. doi: 10.2147/CCIDE.S433519. eCollection 2023. Clin Cosmet Investig Dent. 2023. PMID: 37814630 Free PMC article.
-
The Effect of Sandblasting on Bond Strength of Soft Liners to Denture Base Resins: A Systematic Review and Meta-Analysis of In Vitro Studies.Int J Dent. 2021 Dec 22;2021:5674155. doi: 10.1155/2021/5674155. eCollection 2021. Int J Dent. 2021. PMID: 34976062 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Other Literature Sources