Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 May-Aug;10(2):245-9.
doi: 10.4103/0259-1162.167840.

Comparison of GlideScope video laryngoscope with Macintosh laryngoscope in adult patients undergoing elective surgical procedures

Affiliations

Comparison of GlideScope video laryngoscope with Macintosh laryngoscope in adult patients undergoing elective surgical procedures

Mrunalini Parasa et al. Anesth Essays Res. 2016 May-Aug.

Abstract

Background: GlideScope (GS) is a video laryngoscope that allows a real-time view of the glottis and endotracheal intubation. It provides a better view of the larynx without the need for alignment of the airway axes.

Aim: This prospective randomized comparative study is designed to compare the intubation time, hemodynamic response, and complications associated with intubation using a GS or Macintosh laryngoscope (ML) in adult subjects undergoing elective surgical procedures.

Materials and methods: Sixty American Society of Anesthesiologists physical status 1-2 patients were included in this prospective randomized comparative study. Patients were randomized to be intubated using either a GS or an ML. The primary outcome measure was the intubation time. The secondary outcome measures were the hemodynamic response to intubation and the incidence of mucosal injury.

Statistical analysis: Mean and standard deviation were calculated for different parameters under the study. The observed results were analyzed using Student's t-test for quantitative data and Z-test of proportions. P<0.05 was considered statistically significant.

Results: Intubation time was longer in GS group (45.7033 ± 11.649 s) as compared to ML (27.773 ± 5.122 s) P< 0.0001 with 95% confidence interval (95% CI) -13.2794 to -22.5806. GS provided better Cormack and Lehane laryngoscopic view (P = 0.0016 for grade 1 view) with 95% CI -0.1389 to -0.5951. GS group exhibited more laryngoscopic response than ML group with more increase in blood pressure and heart rate, but the difference was not statistically significant. More cases of mucosal trauma were documented in GS group.

Conclusion: Use of GS to facilitate intubation led to better glottic view but took a longer time to achieve endotracheal intubation. GS was associated with more hemodynamic response to intubation and mucosal injury in comparison with an ML.

Keywords: Cormack and Lehane grade; GlideScope; Macintosh laryngoscope; intubation time.

PubMed Disclaimer

References

    1. Thong SY, Goh SY. Reported complications associated with the use of GlideScope ® video laryngoscope – How can they be prevented? OA Anaesthetics. 2013;1:1–6.
    1. Sun DA, Warriner CB, Parsons DG, Klein R, Umedaly HS, Moult M. The GlideScope video laryngoscope: Randomized clinical trial in 200 patients. Br J Anaesth. 2005;94:381–4. - PubMed
    1. Nasim S, Maharaj CH, Malik MA, O' Donnell J, Higgins BD, Laffey JG. Comparison of the Glidescope® and Pentax AWS® laryngoscopes to the Macintosh laryngoscope for use by Advanced Paramedics in easy and simulated difficult intubation. BMC Emerg Med. 2009;9:1–9. - PMC - PubMed
    1. Healy DW, Maties O, Hovord D, Kheterpal S. A systematic review of the role of videolaryngoscopy in successful orotracheal intubation. BMC Anesthesiol. 2012;12:1–20. - PMC - PubMed
    1. Magboul MM, Joel S. The video laryngoscopes blind spots and possible lingual nerve injury by the gliderite® rigid stylet – Case presentation and review of literature. MEJ Anesth. 2010;20:1–4. - PubMed