Comparative Study
. 2016 Jun;18(2):124.

Bedside lung ultrasound, mobile radiography and physical examination: a comparative analysis of diagnostic tools in the critically ill

Affiliations
  • PMID: 27242110
Comparative Study

Bedside lung ultrasound, mobile radiography and physical examination: a comparative analysis of diagnostic tools in the critically ill

Andrew J Inglis et al. Crit Care Resusc. 2016 Jun.

Abstract

Objective: To compare lung ultrasonography (LUS), chest xray (CXR) and physical examination (Ex) for the detection of pathological abnormalities in the lungs of critically ill patients.

Design, setting and participants: A prospective cohort study of 145 patients in the intensive care unit of a tertiary teaching hospital who were undergoing echocardiography for a clinical indication.

Main outcome measures: Each patient was independently assessed by Ex, CXR and LUS on the same day. Examiners were asked to comment on the presence or absence and severity of pleural effusion, lung consolidation and alveolar interstitial syndrome (AIS). Independent expert examiners performed the LUS and an independent radiologist reported on the CXR.

Results: Ex, CXR and LUS were in fair agreement with each other in detecting a pulmonary abnormality (CXR v LUS, κ = 0.31; CXR v Ex, κ = 0.29; LUS v Ex, κ = 0.22). LUS detected more abnormalities than did CXR (16.2%; χ(2) = 64.1; P < 0.001) or Ex (23.5%; χ(2) = 121.9; P < 0.001). CXR detected more pleural effusions than LUS (9.3%; χ(2) = 7.6; κ = 0.39), but LUS detected more pleural effusions than Ex (22.8%; χ(2) = 36.4; κ = 0.18). There was no significant difference in the performance of LUS and CXR in quantifying the size of a pleural effusion (Z = -1.2; P = 0.23). Ex underestimated size compared with CXR or LUS. LUS detected more consolidation than CXR (17%; χ(2) = 115.9; P < 0.001) and Ex (16.2%; χ(2) = 90.3; P < 0.001). We saw no difference in performance between CXR and Ex in detecting lung consolidation (0.9%; χ(2) = 0.51; P < 0.48). LUS detected more cases of AIS than CXR (5.5%; χ(2) = 7.9; P = 0.005) and Ex (13%; χ(2) = 25.8; P < 0.001).

Conclusions: There was only fair-to-moderate agreement between LUS, CXR and Ex in detecting pulmonary abnormalities, including pleural effusion, lung consolidation and AIS. The higher rate of detection from LUS, combined with its ease of use and increasing accessibility, makes for a powerful diagnostic tool in the ICU.

PubMed Disclaimer

Similar articles

Cited by

Publication types