Editorial: A New Spin on Magnetic Resonance Elastography
- PMID: 27249983
- DOI: 10.1038/ajg.2016.134
Editorial: A New Spin on Magnetic Resonance Elastography
Abstract
The development of hepatic fibrosis is the hallmark of liver disease progression. Identifying fibrosis across the spectrum, from early stages to cirrhosis has become a major unmet need. Newer imaging techniques that measure liver elastography (stiffness) as a surrogate of fibrosis seem to outperform serum tests. The current study compares two-dimensional (2D) gradient-recalled echo magnetic resonance elastography (MRE) to three-dimensional (3D) spin-echo echo-planar imaging MRE. 3D-SE-EPI MRE was able to image more liver volume in less time with fewer technical failures. The current study demonstrates that 3D-SE-EPI MRE appears marginally superior to 2D-GRE and may evolve into the new gold standard.
Comment on
-
Magnetic Resonance Elastography for the Evaluation of Liver Fibrosis in Chronic Hepatitis B and C by Using Both Gradient-Recalled Echo and Spin-Echo Echo Planar Imaging: A Prospective Study.Am J Gastroenterol. 2016 Jun;111(6):823-33. doi: 10.1038/ajg.2016.56. Epub 2016 Mar 15. Am J Gastroenterol. 2016. PMID: 26977760
Similar articles
-
Magnetic Resonance Elastography for the Evaluation of Liver Fibrosis in Chronic Hepatitis B and C by Using Both Gradient-Recalled Echo and Spin-Echo Echo Planar Imaging: A Prospective Study.Am J Gastroenterol. 2016 Jun;111(6):823-33. doi: 10.1038/ajg.2016.56. Epub 2016 Mar 15. Am J Gastroenterol. 2016. PMID: 26977760
-
MR elastography of liver at 3 Tesla: comparison of gradient-recalled echo (GRE) and spin-echo (SE) echo-planar imaging (EPI) sequences and agreement across stiffness measurements.Abdom Radiol (NY). 2019 May;44(5):1825-1833. doi: 10.1007/s00261-019-01932-5. Abdom Radiol (NY). 2019. PMID: 30796479 Free PMC article.
-
Comparison of technical failure of MR elastography for measuring liver stiffness between gradient-recalled echo and spin-echo echo-planar imaging: A systematic review and meta-analysis.J Magn Reson Imaging. 2020 Apr;51(4):1086-1102. doi: 10.1002/jmri.26918. Epub 2019 Aug 27. J Magn Reson Imaging. 2020. PMID: 31456328
-
Spin-echo Echo-planar Imaging MR Elastography versus Gradient-echo MR Elastography for Assessment of Liver Stiffness in Children and Young Adults Suspected of Having Liver Disease.Radiology. 2017 Mar;282(3):761-770. doi: 10.1148/radiol.2016160589. Epub 2016 Oct 10. Radiology. 2017. PMID: 27715486
-
Comparison of gradient-recalled echo and spin-echo echo-planar imaging MR elastography in staging liver fibrosis: a meta-analysis.Eur Radiol. 2018 Apr;28(4):1709-1718. doi: 10.1007/s00330-017-5149-5. Epub 2017 Nov 21. Eur Radiol. 2018. PMID: 29164384 Review.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources