Effect of new light curing units on microleakage and microhardness of resin sealants
- PMID: 27252010
- DOI: 10.4012/dmj.2015-357
Effect of new light curing units on microleakage and microhardness of resin sealants
Abstract
To determine new developed light curing units with shorter curing times effects on microleakage and microhardness values for resin fissure sealants. Resin filled sealant (UltraSeal-XT), resin unfilled sealant (Delton Type-II) and ormocer-based sealant (Admira-Seal) were light cured with a quartz-tungsten-halogen (QTH), two LED light and a high power LED. Two hundred and forty extracted human molars were randomly allocated into four groups according to used light-curing unit and three subgroups were formed for three different fissure sealant materials. Specimens were immersed in 0.5% basic fuchsin for 24 h, sectioned and examined under a stereomicroscope, and scored for marginal microleakage. Knoop hardness number (KHN) readings were measured after 48 h. Statistical analyses of test were found in significant difference both microleakage and microhardness values between the various light curing units. The time saving approaches in the curing light were determined higher microhardness, although it was found in higher microleakage.
Similar articles
-
Effect of light curing methods on microleakage and microhardness of different resin sealants.J Dent Child (Chic). 2011 Jul;78(2):88-95. J Dent Child (Chic). 2011. PMID: 22041113
-
Effect of LED curing on marginal integrity of an ormocer-based sealant.J Dent Child (Chic). 2009 Jan-Apr;76(1):53-7. J Dent Child (Chic). 2009. PMID: 19341580
-
Depth of cure of sealants polymerized with high-power light emitting diode curing lights.Int J Paediatr Dent. 2015 Mar;25(2):79-86. doi: 10.1111/ipd.12102. Epub 2014 Mar 17. Int J Paediatr Dent. 2015. PMID: 24628863
-
Shear Bond Strength and Microleakage of Fissure Sealant to Contaminated and Non-Contaminated Enamel: A Systematic Review and Meta-Analysis of In Vitro Studies.Pediatr Dent. 2023 Sep 15;45(5):30E-47E. Pediatr Dent. 2023. PMID: 37904265
-
Effect of irradiance from curing units on the microhardness of composite - a systematic review.Evid Based Dent. 2022 Oct 17. doi: 10.1038/s41432-022-0824-z. Online ahead of print. Evid Based Dent. 2022. PMID: 36253517 Review.
Cited by
-
Comparison of Light-Emitting Diode-Curing Unit and Halogen-Based Light-Curing Unit for the Polymerization of Orthodontic Resins: An In vitro Study.J Int Soc Prev Community Dent. 2018 Sep-Oct;8(5):409-415. doi: 10.4103/jispcd.JISPCD_302_17. Epub 2018 Oct 8. J Int Soc Prev Community Dent. 2018. PMID: 30430067 Free PMC article.
-
The effect of curing time by conventional quartz tungsten halogens and new light-emitting diodes light curing units on degree of conversion and microhardness of a nanohybrid resin composite.J Conserv Dent. 2019 Mar-Apr;22(2):196-200. doi: 10.4103/JCD.JCD_498_18. J Conserv Dent. 2019. PMID: 31142993 Free PMC article.
-
Effects of delivering the same radiant exposures at 730, 1450, and 2920 mW/cm2 to two resin-based composites.Eur J Dent. 2017 Jan-Mar;11(1):22-28. doi: 10.4103/ejd.ejd_270_16. Eur J Dent. 2017. PMID: 28435361 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources