Ultra-sensitive film sensor based on Al2O3-Au nanoparticles supported on PDDA-functionalized graphene for the determination of acetaminophen
- PMID: 27255103
- DOI: 10.1007/s00216-016-9654-1
Ultra-sensitive film sensor based on Al2O3-Au nanoparticles supported on PDDA-functionalized graphene for the determination of acetaminophen
Abstract
An electrochemical sensor of acetaminophen based on poly(diallyldimethylammonium chloride) (PDDA)-functionalized reduced graphene-loaded Al2O3-Au nanoparticles coated onto glassy carbon electrode (Al2O3-Au/PDDA/reduced graphene oxide (rGO)/glass carbon electrode (GCE)) were prepared by layer self-assembly technique. The as-prepared electrode-modified materials were characterized by scanning electron microscopy, X-ray powder diffraction, and Fourier transform infrared spectroscopy. The electrocatalytic performances of Al2O3-Au/PDDA/rGO-modified glassy carbon electrode toward the acetaminophen were investigated by cyclic voltammetry and differential pulse voltammetry. The modified electrodes of graphene oxide (GO)/GCE, PDDA/rGO/GCE, and Al2O3-Au/PDDA/rGO/GCE were constructed for comparison and learning the catalytic mechanism. The research showed Al2O3-Au/PDDA/rGO/GCE having good electrochemical performance, attributing to the synergetic effect that comes from the special nanocomposite structure and physicochemical properties of Al2O3-Au nanoparticles and graphene. A low detection limit of 6 nM (S/N = 3) and a wide linear detection range from 0.02 to 200 μM (R (2) = 0.9970) was obtained. The preparation of sensor was successfully applied for the detection of acetaminophen in commercial pharmaceutical pills. Graphical abstract Schematic diagram of synthesis of Al2O3-Au/PDDA/rGO/GCE.
Keywords: Acetaminophen; Aluminum oxide; Gold nanoparticles; Poly diallyl dimethyl ammonium chloride.
Similar articles
-
Electrochemical sensor for Isoniazid based on the glassy carbon electrode modified with reduced graphene oxide-Au nanomaterials.Mater Sci Eng C Mater Biol Appl. 2015 Dec 1;57:197-204. doi: 10.1016/j.msec.2015.07.045. Epub 2015 Jul 27. Mater Sci Eng C Mater Biol Appl. 2015. PMID: 26354255
-
Sensitive detection of acetaminophen based on Fe₃O₄ nanoparticles-coated poly(diallyldimethylammonium chloride)-functionalized graphene nanocomposite film.Talanta. 2012 Jan 15;88:181-6. doi: 10.1016/j.talanta.2011.10.029. Epub 2011 Oct 25. Talanta. 2012. PMID: 22265485
-
Nano-assemblies consisting of Pd/Pt nanodendrites and poly (diallyldimethylammonium chloride)-coated reduced graphene oxide on glassy carbon electrode for hydrogen peroxide sensors.Mater Sci Eng C Mater Biol Appl. 2016 Jan 1;58:1246-54. doi: 10.1016/j.msec.2015.09.015. Epub 2015 Sep 7. Mater Sci Eng C Mater Biol Appl. 2016. PMID: 26478428
-
Ag and Au nanoparticles/reduced graphene oxide composite materials: Synthesis and application in diagnostics and therapeutics.Adv Colloid Interface Sci. 2019 Sep;271:101991. doi: 10.1016/j.cis.2019.101991. Epub 2019 Jul 17. Adv Colloid Interface Sci. 2019. PMID: 31376639 Review.
-
Electrochemical sensing of nicotine using CuWO4 decorated reduced graphene oxide immobilized glassy carbon electrode.Ultrason Sonochem. 2019 Jul;55:196-206. doi: 10.1016/j.ultsonch.2019.01.038. Epub 2019 Jan 29. Ultrason Sonochem. 2019. PMID: 30878204 Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources