Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Jan;42(1):41-46.
doi: 10.3109/02713683.2016.1151054. Epub 2016 Jun 7.

Evaluations of Corneas in Eyes with Isolated Iris Coloboma

Affiliations

Evaluations of Corneas in Eyes with Isolated Iris Coloboma

Arzu Seyhan Karatepe Haşhaş et al. Curr Eye Res. 2017 Jan.

Abstract

Purpose: We aimed to evaluate the differences in the corneas of eyes with isolated iris coloboma.

Methods: This study was designed as a prospective study. Among patients who applied to our hospital within the last 3-year period, those with isolated iris coloboma in one eye and a completely normal contralateral eye were included in the study. In addition to a complete ophthalmologic examination, all patients were scanned by Pentacam Scheimpflug camera in the dark, and a corneal endothelium cell count was taken using a Topcon Specular Microscope. Data entered using SPSS software were then evaluated by paired t-test; p < 0.05 value was considered statistically significant.

Results: Nine patients, seven men and two women, with a mean age of 35.77 ± 22.50 (range 8-60) years, were included in the study. In comparison to normal eyes, the colobomatous eyes were statistically found to have lower keratometry values in diopters (43.82 ± 2.17, 44.46 ± 1.86; p = 0.040), a greater negative asphericity (Q value) (-0.38 ± 0.07, -0.22 ± 0.20; p = 0.042), increased corneal thickness (569.78 ± 25.42, 537.33 ± 27.36; p < 0.001), decreased anterior chamber depth (2.50 ± 0.32, 2.81 ± 0.50; p = 0.005), a shallower angle (30.51 ± 10.68, 35.29 ± 9.99; p = 0.057), higher best-fit sphere (BFS) values of the anterior and posterior corneal surfaces (7.88 ± 0.39, 7.67 ± 0.37; p = 0.001; 6.40 ± 0.26, 6.23 ± 0.19; p = 0.006), larger pupil diameter (3.48 ± 0.49, 2.80 ± 0.34; p = 0.001), smaller horizontal corneal diameter (HCD) (11.06 ± 0.42; 11.26 ± 0.45; p = 0.009), and higher value of endothelial cell density (ECD) (3161 ± 431; 2923 ± 590; p = 0.031).

Conclusion: We have determined that a number of factors such as keratometry values, particularly of the corneal endothelium, are different from those of normal eyes. These differences should be taken into account in the follow-up and treatment of eyes with iris coloboma.

Keywords: Coloboma; cornea; iris.

PubMed Disclaimer

LinkOut - more resources