Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Jan;57(1):85-95.
doi: 10.1002/jcph.779. Epub 2016 Jul 7.

Can Bias Evaluation Provide Protection Against False-Negative Results in QT Studies Without a Positive Control Using Exposure-Response Analysis?

Affiliations

Can Bias Evaluation Provide Protection Against False-Negative Results in QT Studies Without a Positive Control Using Exposure-Response Analysis?

Georg Ferber et al. J Clin Pharmacol. 2017 Jan.

Abstract

The revised ICH E14 document allows the use of exposure-response analysis to exclude a small QT effect of a drug. If plasma concentrations exceeding clinically relevant levels is achieved, a positive control is not required. In cases when this cannot be achieved, there may be a need for metrics to protect against false-negative results. The objectives of this study were to create bias in electrocardiogram laboratory QT-interval measurements and define a metric that can be used to detect bias severe enough to cause false-negative results using exposure-response analysis. Data from the IQ-CSRC study, which evaluated the QT effect of 5 QT-prolonging drugs, were used. Negative bias using 3 deterministic and 2 random methods was introduced into the reported QTc values and compared with fully automated data from the underlying electrocardiogram algorithm (COMPAS). The slope estimate of the Bland-Altman plot was used as a bias metric. With the deterministic bias methods, negative bias, measured between electrocardiogram laboratory values and COMPAS, had to be larger than approximately -20 milliseconds over a QTcF range of 100 milliseconds to cause failures to predict the QT effect of ondansetron, quinine, dolasetron, moxifloxacin, and dofetilide. With the random methods, the rate of false-negatives was ≤5% with bias severity < -10 milliseconds for all 5 drugs when plasma levels exceeded those of interest. Severe and therefore detectable bias has to be introduced into reported QTc values to cause false-negative predictions with exposure-response analysis.

Keywords: QT; bias; early phase; exposure response analysis; first-in-human; positive control.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources