Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Mar;26(3):720-725.
doi: 10.1007/s00586-016-4639-5. Epub 2016 Jun 7.

Robotic-guided sacro-pelvic fixation using S2 alar-iliac screws: feasibility and accuracy

Affiliations

Robotic-guided sacro-pelvic fixation using S2 alar-iliac screws: feasibility and accuracy

Xiaobang Hu et al. Eur Spine J. 2017 Mar.

Abstract

Purpose: To review our experience with robotic guided S2-alar iliac (S2AI) screw placement.

Methods: We retrospectively reviewed patients who underwent S2AI fixation with robotic guidance. Screw placement and deviation from the preoperative plan were assessed by fusing preoperative CT (with the planned S2AI screws) to postoperative CT. The software's measurement tool was used to compare the planned vs. actual screw placements in axial and lateral views, at entry point to the S2 pedicle and at a 30 mm depth at the screws' mid-shaft, in a resolution of 0.1 mm. Medical charts were reviewed for technical issues and intra-operative complications.

Results: 35 S2AI screws were reviewed in 18 patients. The patients' mean age was 60 years. No intra-operative complications that related to the placement of S2AI screws were reported and robotic guidance was successful in all 35 screws. Post-operative CT scans showed that all trajectories were accurate. No violations of the iliac cortex or breaches of the anterior sacrum were noted. At the entry point, the screw deviated from the pre-operative plan by 3.0 ± 2.2 mm in the axial plane and 1.8 ± 1.6 mm in the lateral plane. At 30 mm depth, the screw deviated from the pre-operative plan by 2.1 ± 1.3 mm in the axial plane and 1.2 ± 1.1 mm in the lateral plane.

Conclusions: Robotic guided S2AI screw placement is feasible and accurate. No screw malpositions or complications that related to the placement of S2AI screws occurred in this series. Larger studies are needed to assess the long-term clinical outcomes of robotic guided sacral-pelvic fixation.

Keywords: Accuracy; Adult spinal deformity; Robotic guidance; S2-alar iliac screw.

PubMed Disclaimer

References

    1. Clin Spine Surg. 2017 May;30(4):E430-E439 - PubMed
    1. Clin Orthop Relat Res. 2014 Jun;472(6):1839-44 - PubMed
    1. Spine (Phila Pa 1976). 2010 Sep 15;35(20):1887-92 - PubMed
    1. Neurosurgery. 2007 Feb;60(2 Suppl 1):ONS129-39; discussion ONS139 - PubMed
    1. Spine (Phila Pa 1976). 2012 Feb 1;37(3):E188-94 - PubMed

LinkOut - more resources