Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 Aug;55(3):401-10.
doi: 10.1007/s00411-016-0656-3. Epub 2016 Jun 11.

Attached, unattached fraction of progeny concentrations and equilibrium factor for dose assessments from (222)Rn and (220)Rn

Affiliations

Attached, unattached fraction of progeny concentrations and equilibrium factor for dose assessments from (222)Rn and (220)Rn

Parminder Singh et al. Radiat Environ Biophys. 2016 Aug.

Abstract

In this study, measurements of indoor radon ((222)Rn), thoron ((220)Rn) and their equilibrium equivalent concentration (EEC) were carried out in 96 dwellings from 22 different villages situated in Hamirpur district, Himachal Pradesh, India, by using LR-115 type II-based pinhole twin cup dosimeters and deposition-based progeny sensors (DRPS/DTPS). The annual average indoor (222)Rn and (220)Rn concentrations observed in these dwellings were 63.82 and 89.59 Bq/m(3), respectively, while the average EEC (attached + unattached) for (222)Rn and (220)Rn was 29.28 and 2.74 Bq/m(3). For (222)Rn (f Rn) and (220)Rn (f Tn), the average values of unattached fraction were 0.11 and 0.09, respectively. The equilibrium factors for radon (F Rn) and thoron (F Tn) varied from 0.12 to 0.77 with an average of 0.50, and from 0.01 to 0.34 with an average of 0.05, respectively. The annual inhalation dose due to mouth and nasal breathing was calculated using dose conversion factors and unattached fractions. The indoor annual effective doses for (222)Rn (AEDR) and (220)Rn (AEDT) were found to be 1.92 and 0.83 mSv a(-1), respectively. The values of (222)Rn/(220)Rn concentrations and annual effective doses obtained in the present study are within the safe limits as recommended by the International Commission on Radiological Protection for indoor dwelling exposure conditions.

Keywords: DCF; EEC; Effective dose; Equilibrium factor; Unattached fraction.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Ann ICRP. 2010 Feb;40(1):1-64 - PubMed
    1. Radiat Prot Dosimetry. 2001;94(4):365-73 - PubMed
    1. Radiat Prot Dosimetry. 2005;113(2):233-5 - PubMed
    1. Radiat Res. 1999 Dec;152(6 Suppl):S145-8 - PubMed
    1. Sci Total Environ. 2010 Dec 15;409(2):378-83 - PubMed

Publication types

LinkOut - more resources