Torque and mechanomyogram relationships during electrically-evoked isometric quadriceps contractions in persons with spinal cord injury
- PMID: 27289541
- DOI: 10.1016/j.medengphy.2016.05.012
Torque and mechanomyogram relationships during electrically-evoked isometric quadriceps contractions in persons with spinal cord injury
Abstract
The interaction between muscle contractions and joint loading produces torques necessary for movements during activities of daily living. However, during neuromuscular electrical stimulation (NMES)-evoked contractions in persons with spinal cord injury (SCI), a simple and reliable proxy of torque at the muscle level has been minimally investigated. Thus, the purpose of this study was to investigate the relationships between muscle mechanomyographic (MMG) characteristics and NMES-evoked isometric quadriceps torques in persons with motor complete SCI. Six SCI participants with lesion levels below C4 [(mean (SD) age, 39.2 (7.9) year; stature, 1.71 (0.05) m; and body mass, 69.3 (12.9) kg)] performed randomly ordered NMES-evoked isometric leg muscle contractions at 30°, 60° and 90° knee flexion angles on an isokinetic dynamometer. MMG signals were detected by an accelerometer-based vibromyographic sensor placed over the belly of rectus femoris muscle. The relationship between MMG root mean square (MMG-RMS) and NMES-evoked torque revealed a very high association (R(2)=0.91 at 30°; R(2)=0.98 at 60°; and R(2)=0.97 at 90° knee angles; P<0.001). MMG peak-to-peak (MMG-PTP) and stimulation intensity were less well related (R(2)=0.63 at 30°; R(2)=0.67 at 60°; and R(2)=0.45 at 90° knee angles), although were still significantly associated (P≤0.006). Test-retest interclass correlation coefficients (ICC) for the dependent variables ranged from 0.82 to 0.97 for NMES-evoked torque, between 0.65 and 0.79 for MMG-RMS, and from 0.67 to 0.73 for MMG-PTP. Their standard error of measurements (SEM) ranged between 10.1% and 31.6% (of mean values) for torque, MMG-RMS and MMG-PTP. The MMG peak frequency (MMG-PF) of 30Hz approximated the stimulation frequency, indicating NMES-evoked motor unit firing rate. The results demonstrated knee angle differences in the MMG-RMS versus NMES-isometric torque relationship, but a similar torque related pattern for MMG-PF. These findings suggested that MMG was well associated with torque production, reliably tracking the motor unit recruitment pattern during NMES-evoked muscle contractions. The strong positive relationship between MMG signal and NMES-evoked torque production suggested that the MMG might be deployed as a direct proxy for muscle torque or fatigue measurement during leg exercise and functional movements in the SCI population.
Keywords: Mechanomyogram; Motor unit recruitment; Muscle torque; NMES-evoked muscle contractions; Spinal cord injury.
Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.
Similar articles
-
Assessment of muscle activity using electrical stimulation and mechanomyography: a systematic review.Biomed Eng Online. 2021 Jan 3;20(1):1. doi: 10.1186/s12938-020-00840-w. Biomed Eng Online. 2021. PMID: 33390158 Free PMC article.
-
SVR modelling of mechanomyographic signals predicts neuromuscular stimulation-evoked knee torque in paralyzed quadriceps muscles undergoing knee extension exercise.Comput Biol Med. 2020 Feb;117:103614. doi: 10.1016/j.compbiomed.2020.103614. Epub 2020 Jan 11. Comput Biol Med. 2020. PMID: 32072969
-
Neural Network-Based Muscle Torque Estimation Using Mechanomyography During Electrically-Evoked Knee Extension and Standing in Spinal Cord Injury.Front Neurorobot. 2018 Aug 10;12:50. doi: 10.3389/fnbot.2018.00050. eCollection 2018. Front Neurorobot. 2018. PMID: 30147650 Free PMC article.
-
Mechanomyography responses characterize altered muscle function during electrical stimulation-evoked cycling in individuals with spinal cord injury.Clin Biomech (Bristol). 2018 Oct;58:21-27. doi: 10.1016/j.clinbiomech.2018.06.020. Epub 2018 Jul 2. Clin Biomech (Bristol). 2018. PMID: 30005423
-
Effect of muscle length on maximum evoked torque, discomfort, contraction fatigue, and strength adaptations during electrical stimulation in adult populations: A systematic review.PLoS One. 2024 Jun 10;19(6):e0304205. doi: 10.1371/journal.pone.0304205. eCollection 2024. PLoS One. 2024. PMID: 38857245 Free PMC article.
Cited by
-
Mechanomyography and Torque during FES-Evoked Muscle Contractions to Fatigue in Individuals with Spinal Cord Injury.Sensors (Basel). 2017 Jul 14;17(7):1627. doi: 10.3390/s17071627. Sensors (Basel). 2017. PMID: 28708068 Free PMC article.
-
Mechanomyography-based muscle fatigue detection during electrically elicited cycling in patients with spinal cord injury.Med Biol Eng Comput. 2019 Jun;57(6):1199-1211. doi: 10.1007/s11517-019-01949-4. Epub 2019 Jan 28. Med Biol Eng Comput. 2019. PMID: 30687901
-
Effect of Forearm Postures and Elbow Joint Angles on Elbow Flexion Torque and Mechanomyography in Neuromuscular Electrical Stimulation of the Biceps Brachii.Sensors (Basel). 2023 Sep 29;23(19):8165. doi: 10.3390/s23198165. Sensors (Basel). 2023. PMID: 37836995 Free PMC article.
-
Assessment of muscle activity using electrical stimulation and mechanomyography: a systematic review.Biomed Eng Online. 2021 Jan 3;20(1):1. doi: 10.1186/s12938-020-00840-w. Biomed Eng Online. 2021. PMID: 33390158 Free PMC article.
-
Physiological factors affecting the mechanical performance of peripheral muscles: A perspective for long COVID patients through a systematic literature review.Front Physiol. 2022 Oct 12;13:958333. doi: 10.3389/fphys.2022.958333. eCollection 2022. Front Physiol. 2022. PMID: 36324314 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical