. 2016 Jul;40(7):181.
doi: 10.1007/s10916-016-0539-9. Epub 2016 Jun 14.

Lung Cancer Detection Using Fuzzy Auto-Seed Cluster Means Morphological Segmentation and SVM Classifier

Affiliations

Lung Cancer Detection Using Fuzzy Auto-Seed Cluster Means Morphological Segmentation and SVM Classifier

T Manikandan et al. J Med Syst. 2016 Jul.

Abstract

An effective fuzzy auto-seed cluster means morphological algorithm developed in this work to segment the lung nodules from the consecutive slices of Computer Tomography (CT) images to detect the lung cancer. The initial cluster values were chosen automatically by averaging the minimum and maximum pixel values in each row of an image. The area and eccentricity features were used to eliminate the line like structure and very tiny clusters less than 3 mm in size. The change in centroid analysis was carried out to eliminate the blood vessels. The tissue clusters whose centroid varies much in consecutive slices must be blood vessels. After eliminating the blood vessels, the co-occurrence matrix based texture features contrast, homogeneity and auto correlation were computed on the remaining nodules from the consecutive CT slices to discriminate the calcifications. The extracted centroid shift and texture features were used as the inputs to the Support Vector Machine (SVM) kernel classifier in order to classify the real malignant nodules. This work was carried out on 56 malignant (cancerous) cases and 50 normal cases (with lung infections), which had a total of 56 malignant nodules and 745 benign nodules. Out of these, 60 % of subjects (34 cancerous & 30 non-cancerous) were used for training. The remaining 40 % subjects (22 cancerous & 20 non-cancerous) were used for testing. This work produced a good sensitivity, specificity and accuracy of 100 %, 93 % and 94 %, respectively. The False Positive (FP) per patient was calculated as 0.38.

Keywords: Cad; Cluster; Computed tomography; Lung cancer; Morphology; Nodules.

PubMed Disclaimer

References

    1. Comput Methods Programs Biomed. 2014;113(1):202-9 - PubMed
    1. Comput Methods Programs Biomed. 2010 Apr;98 (1):1-14 - PubMed
    1. Comput Biol Med. 2009 Oct;39(10 ):921-33 - PubMed
    1. Int J Biomed Sci. 2013 Mar;9(1):9-17 - PubMed
    1. Proc Inst Mech Eng H. 2016 Jan;230(1):58-70 - PubMed

MeSH terms