. 2016 Dec;51(12):776-785.
doi: 10.1097/RLI.0000000000000291.

Characterization of a Novel Hafnium-Based X-ray Contrast Agent

Affiliations

Characterization of a Novel Hafnium-Based X-ray Contrast Agent

Thomas Frenzel et al. Invest Radiol. 2016 Dec.

Abstract

Objective: Characterization of BAY-576, a new x-ray contrast agent which is not based on iodine, but rather on the heavy metal hafnium. Compared with iodine, hafnium provides better x-ray absorption in the energy range of computed tomography (CT) and allows images of comparable quality to be acquired at a significantly reduced radiation dose.

Materials and methods: A range of standard methods were used to explore the physicochemistry of BAY-576 as well as its tolerability in in vitro assays, its pharmacokinetics and toxicology in rats, and its performance in CT imaging in rabbits.

Results: BAY-576 is an extraordinarily stable chelate with a metal content of 42% (wt/wt) and with excellent water solubility. Formulations of 300 mg Hf/mL exhibited viscosity (3.3-3.6 mPa) and osmolality (860-985 mOsm/kg) in the range of nonionic x-ray agents. No relevant effects on erythrocytes, the coagulation, or complement system or on a panel of 87 potential biological targets were observed. The compound did not bind to plasma proteins of a number of species investigated. After intravenous injection in rats, it was excreted fast and mainly via the kidneys. Its pharmacokinetics was comparable to known extracellular contrast agents. A dose of 6000 mg Hf/kg, approximately 10 to 20 times the expected diagnostic dose, was well tolerated by rats with only moderate adverse effects. Computed tomography imaging in rabbits bearing a tumor in the liver demonstrated excellent image quality when compared with iopromide at the same contrast agent dose in angiography during the arterial phase. At 70% of the radiation dose, BAY-576 provided a contrast-to-noise ratio of the tumor, which was equivalent to iopromide at 100% radiation dose.

Conclusions: The profile of BAY-576 indicates its potential as the first compound in a new class of noniodine x-ray contrast agents, which can contribute to the reduction of the radiation burden in contrast-enhanced CT imaging.