Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Aug;28(8):893-901.
doi: 10.1111/clr.12894. Epub 2016 Jun 17.

Hydrophilic surface of Ti6Al4V-ELI alloy improves the early bone apposition of sheep tibia

Affiliations

Hydrophilic surface of Ti6Al4V-ELI alloy improves the early bone apposition of sheep tibia

Suelen C Sartoretto et al. Clin Oral Implants Res. 2017 Aug.

Abstract

Objective: The aim of this preclinical study was to compare histologically and histomorphometrically both sandblasted/acid-etched implant surfaces with or without maintained in an isotonic solution of 0.9% sodium chloride in early stages of osseointegration.

Material and methods: Both implant surfaces were composed of a titanium/aluminum/vanadium alloy (Ti6Al4V-ELI), but they had different surface chemistries: sandblasted/acid-etched titanium surface (FN) or sandblasted/acid-etched surface maintained in an isotonic solution of 0.9% sodium chloride (FA). The surface morphology, topography and chemistry were evaluated by scanning electron microscopy (SEM), confocal microscopy (CM) and X-ray photoelectron spectroscopy (XPS), respectively. Dynamic contact angle (DCA) was employed for wettability evaluation. One implant from each group was placed in the left tibia of twenty healthy, skeletally mature Santa Ines sheep (n = 5). Bone area (BA) and bone-to-implant contact (BIC) were performed on thin sections (30 μm) at 7, 14, 21 and 28 days after implant installation.

Results: Despite the roughness and morphology similarities between the groups, at the XPS evaluation, the FA group presented 2.3 times less carbon on the surface (FN: 27.3% and FA: 11.6%), sharply enhanced hydrophilicity and significantly enhanced BA and BIC at 14, 21 and 28 days of healing (P < 0.05) compared with the FN.

Conclusion: The data suggest that the hydrophilic FA accelerates the BA apposition and BIC interface around the implants during early stages of bone formation, providing highest degree of osseointegration.

Keywords: Ti6Al4V-ELI alloy; dental implants; hydrophilicity; osseointegration; sheep.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources