Clinical Trial
. 2016 Aug 1:75:217-34.
doi: 10.1016/j.compbiomed.2016.06.010. Epub 2016 Jun 10.

Accurate cloud-based smart IMT measurement, its validation and stroke risk stratification in carotid ultrasound: A web-based point-of-care tool for multicenter clinical trial

Affiliations
Clinical Trial

Accurate cloud-based smart IMT measurement, its validation and stroke risk stratification in carotid ultrasound: A web-based point-of-care tool for multicenter clinical trial

Luca Saba et al. Comput Biol Med. .

Abstract

This study presents AtheroCloud™ - a novel cloud-based smart carotid intima-media thickness (cIMT) measurement tool using B-mode ultrasound for stroke/cardiovascular risk assessment and its stratification. This is an anytime-anywhere clinical tool for routine screening and multi-center clinical trials. In this pilot study, the physician can upload ultrasound scans in one of the following formats (DICOM, JPEG, BMP, PNG, GIF or TIFF) directly into the proprietary cloud of AtheroPoint from the local server of the physician's office. They can then run the intelligent and automated AtheroCloud™ cIMT measurements in point-of-care settings in less than five seconds per image, while saving the vascular reports in the cloud. We statistically benchmark AtheroCloud™ cIMT readings against sonographer (a registered vascular technologist) readings and manual measurements derived from the tracings of the radiologist. One hundred patients (75 M/25 F, mean age: 68±11 years), IRB approved, Toho University, Japan, consisted of Left/Right common carotid artery (CCA) artery (200 ultrasound scans), (Toshiba, Tokyo, Japan) were collected using a 7.5MHz transducer. The measured cIMTs for L/R carotid were as follows (in mm): (i) AtheroCloud™ (0.87±0.20, 0.77±0.20); (ii) sonographer (0.97±0.26, 0.89±0.29) and (iii) manual (0.90±0.20, 0.79±0.20), respectively. The coefficient of correlation (CC) between sonographer and manual for L/R cIMT was 0.74 (P<0.0001) and 0.65 (P<0.0001), while, between AtheroCloud™ and manual was 0.96 (P<0.0001) and 0.97 (P<0.0001), respectively. We observed that 91.15% of the population in AtheroCloud™ had a mean cIMT error less than 0.11mm compared to sonographer's 68.31%. The area under curve for receiving operating characteristics was 0.99 for AtheroCloud™ against 0.81 for sonographer. Our Framingham Risk Score stratified the population into three bins as follows: 39% in low-risk, 70.66% in medium-risk and 10.66% in high-risk bins. Statistical tests were performed to demonstrate consistency, reliability and accuracy of the results. The proposed AtheroCloud™ system is completely reliable, automated, fast (3-5 seconds depending upon the image size having an internet speed of 180Mbps), accurate, and an intelligent, web-based clinical tool for multi-center clinical trials and routine telemedicine clinical care.

Keywords: Atherosclerosis; Automated; Carotid; Cloud; Pharmaceutical trails; Precision of merit; ROC; Routine; Stroke; Telemedicine; Ultrasound; Web-based; cIMT; reliable.