Automated Adaptive Brightness in Wireless Capsule Endoscopy Using Image Segmentation and Sigmoid Function
- PMID: 27333609
- DOI: 10.1109/TBCAS.2016.2546838
Automated Adaptive Brightness in Wireless Capsule Endoscopy Using Image Segmentation and Sigmoid Function
Abstract
Wireless capsule endoscopy (WCE) plays an important role in the diagnosis of gastrointestinal (GI) diseases by capturing images of human small intestine. Accurate diagnosis of endoscopic images depends heavily on the quality of captured images. Along with image and frame rate, brightness of the image is an important parameter that influences the image quality which leads to the design of an efficient illumination system. Such design involves the choice and placement of proper light source and its ability to illuminate GI surface with proper brightness. Light emitting diodes (LEDs) are normally used as sources where modulated pulses are used to control LED's brightness. In practice, instances like under- and over-illumination are very common in WCE, where the former provides dark images and the later provides bright images with high power consumption. In this paper, we propose a low-power and efficient illumination system that is based on an automated brightness algorithm. The scheme is adaptive in nature, i.e., the brightness level is controlled automatically in real-time while the images are being captured. The captured images are segmented into four equal regions and the brightness level of each region is calculated. Then an adaptive sigmoid function is used to find the optimized brightness level and accordingly a new value of duty cycle of the modulated pulse is generated to capture future images. The algorithm is fully implemented in a capsule prototype and tested with endoscopic images. Commercial capsules like Pillcam and Mirocam were also used in the experiment. The results show that the proposed algorithm works well in controlling the brightness level accordingly to the environmental condition, and as a result, good quality images are captured with an average of 40% brightness level that saves power consumption of the capsule.
Similar articles
-
Adaptive Image Enhancement Based on Guide Image and Fraction-Power Transformation for Wireless Capsule Endoscopy.IEEE Trans Biomed Circuits Syst. 2018 Oct;12(5):993-1003. doi: 10.1109/TBCAS.2018.2869530. IEEE Trans Biomed Circuits Syst. 2018. PMID: 30346276
-
An Ingenious Design of a High Performance-Low Complexity Image Compressor for Wireless Capsule Endoscopy.Sensors (Basel). 2020 Mar 14;20(6):1617. doi: 10.3390/s20061617. Sensors (Basel). 2020. PMID: 32183258 Free PMC article.
-
Hardware image assessment for wireless endoscopy capsules.Annu Int Conf IEEE Eng Med Biol Soc. 2016 Aug;2016:2050-2053. doi: 10.1109/EMBC.2016.7591130. Annu Int Conf IEEE Eng Med Biol Soc. 2016. PMID: 28268733
-
Computer vision-based solutions to overcome the limitations of wireless capsule endoscopy.J Med Eng Technol. 2023 Apr-May;47(4):242-261. doi: 10.1080/03091902.2024.2302025. Epub 2024 Jan 22. J Med Eng Technol. 2023. PMID: 38231042 Review.
-
Magnetically guided capsule endoscopy.Med Phys. 2017 Aug;44(8):e91-e111. doi: 10.1002/mp.12299. Epub 2017 Jun 23. Med Phys. 2017. PMID: 28437000 Review.
Cited by
-
Methodological Considerations for Assessing Automatic Brightness Control in Endoscopy: Experimental Study.Sensors (Basel). 2023 May 20;23(10):4932. doi: 10.3390/s23104932. Sensors (Basel). 2023. PMID: 37430846 Free PMC article.
-
A Fluorescence-Based Wireless Capsule Endoscopy System for Detecting Colorectal Cancer.Cancers (Basel). 2020 Apr 6;12(4):890. doi: 10.3390/cancers12040890. Cancers (Basel). 2020. PMID: 32268557 Free PMC article.
-
Multivariate Gaussian Bayes classifier with limited data for segmentation of clean and contaminated regions in the small bowel capsule endoscopy images.PLoS One. 2025 Mar 7;20(3):e0315638. doi: 10.1371/journal.pone.0315638. eCollection 2025. PLoS One. 2025. PMID: 40053533 Free PMC article.
-
An improved advertising CTR prediction approach based on the fuzzy deep neural network.PLoS One. 2018 May 4;13(5):e0190831. doi: 10.1371/journal.pone.0190831. eCollection 2018. PLoS One. 2018. PMID: 29727443 Free PMC article.
-
LED-based, real-time, hyperspectral imaging device.J Med Imaging (Bellingham). 2025 May;12(3):035002. doi: 10.1117/1.JMI.12.3.035002. Epub 2025 Jun 12. J Med Imaging (Bellingham). 2025. PMID: 40521235
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources