. 2016 Sep 1:76:1-6.
doi: 10.1016/j.compbiomed.2016.06.012. Epub 2016 Jun 11.

Image-guided automatic triggering of a fractional CO2 laser in aesthetic procedures

Affiliations

Image-guided automatic triggering of a fractional CO2 laser in aesthetic procedures

Sławomir Wilczyński et al. Comput Biol Med. .

Abstract

Background: Laser procedures in dermatology and aesthetic medicine are associated with the need for manual laser triggering. This leads to pulse overlapping and side effects.

Methods: Automatic laser triggering based on image analysis can provide a secure fit to each successive doses of radiation. A fractional CO2 laser was used in the study. 500 images of the human skin of healthy subjects were acquired. Automatic triggering was initiated by an application together with a camera which tracks and analyses the skin in visible light. The tracking algorithm uses the methods of image analysis to overlap images. After locating the characteristic points in analysed adjacent areas, the correspondence of graphs is found. The point coordinates derived from the images are the vertices of graphs with respect to which isomorphism is sought. When the correspondence of graphs is found, it is possible to overlap the neighbouring parts of the image.

Results: The proposed method of laser triggering owing to the automatic image fitting method allows for 100% repeatability. To meet this requirement, there must be at least 13 graph vertices obtained from the image. For this number of vertices, the time of analysis of a single image is less than 0.5s.

Conclusions: The proposed method, applied in practice, may help reduce the number of side effects during dermatological laser procedures resulting from laser pulse overlapping. In addition, it reduces treatment time and enables to propose new techniques of treatment through controlled, precise laser pulse overlapping.

Keywords: Ablative lasers; Automatic laser triggering; CO(2) laser; Image processing.