Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2017 Mar;42(3):436-442.
doi: 10.1080/02713683.2016.1185130. Epub 2016 Jun 27.

Pars Plana-Modified versus Conventional Ahmed Glaucoma Valve in Patients Undergoing Penetrating Keratoplasty: A Prospective Comparative Randomized Study

Affiliations
Randomized Controlled Trial

Pars Plana-Modified versus Conventional Ahmed Glaucoma Valve in Patients Undergoing Penetrating Keratoplasty: A Prospective Comparative Randomized Study

Jitendra Kumar Singh Parihar et al. Curr Eye Res. 2017 Mar.

Abstract

Purpose: To compare the outcome of pars-plana-modified Ahmed glaucoma valve (AGV) versus limbal-based conventional AGV into the anterior chamber, in patients undergoing penetrating keratoplasty (PK) for glaucoma with coexisting corneal diseases.

Method: In this prospective randomized clinical trial, 58 eyes of 58 patients with glaucoma and coexisting corneal disease were divided into two groups. Group 1 (29 eyes of 29 patients) included patients undergoing limbal-based conventional AGV into the anterior chamber (AC) along-with PK and group 2 (29 eyes of 29 patients) included those undergoing pars-plana-modified AGV along-with PK. Outcome measures included corneal graft clarity, intraocular pressure (IOP), number of antiglaucoma medications, and postoperative complications. Patients were followed up for a minimum period of 2 years.

Results: Out of 58 eyes (58 patients), 50 eyes (50 patients: 25 eyes of 25 patients each in group 1 and group 2) completed the study and were analyzed. Complete success rate for AGV (group 1: 76%; group 2: 72%; p = 0.842) and corneal graft clarity (group 1: 68%; group 2: 76%; p = 0.081) were comparable between the two groups at 2 years. Graft failure was more in conventional AGV (32%) as compared to pars plana-modified AGV (24%) but not statistically significant (p = 0.078) at 2 years.

Conclusion: Though both procedures were comparable in various outcome measures, pars-plana-modified AGV is a viable option for patients undergoing PK, as it provides a relatively better corneal graft survival rate and lesser complications that were associated with conventional AGV.

Keywords: Ahmed glaucoma valve (AGV); glaucoma drainage device (GDD); glaucoma with coexisting corneal diseases; pars plana clip; pars plana-modified AGV; penetrating keratoplasty.