Comparative Study
. 2016 Aug;71(8):892-900.
doi: 10.1111/anae.13522. Epub 2016 Jun 29.

General anaesthesia vs. conscious sedation for transfemoral aortic valve implantation: a single UK centre before-and-after study

Affiliations
Free article
Comparative Study

General anaesthesia vs. conscious sedation for transfemoral aortic valve implantation: a single UK centre before-and-after study

L F Miles et al. Anaesthesia. 2016 Aug.
Free article

Abstract

Reported data suggest that 99% of transfemoral, transcatheter aortic valve implantations in the UK are performed under general anaesthesia. This before-and-after study is the first UK comparison of conscious sedation vs. general anaesthesia for this procedure. Patients who underwent general anaesthesia received tracheal intubation, positive pressure ventilation, radial arterial and central venous access and urinary catheterisation. Anaesthesia was maintained with propofol or sevoflurane. Patients who received conscious sedation had a fascia iliaca and ilioinguinal nerve block and low-dose remifentanil infusion, without invasive monitoring or urinary catheterisation. Recruitment took place between August 2012 and July 2015, with a 6-month crossover period between November 2013 and June 2014. A total of 88 patients were analysed, evenly divided between the two groups. Patients receiving conscious sedation had a shorter anaesthetic time (mean (SD) 121 (28) min vs. 145 (41) min; p < 0.001) and recovery room time (110 (50) min vs. 155 (48) min; p = 0.001), lower requirement for inotropes (4.6% vs 81.8%; OR (95% CI) 0.1 (0.002-0.050); p < 0.001) and a lower incidence of malignant dysrhythmia (0% vs 11.4%; p = 0.020). Conscious sedation appears a feasible alternative to general anaesthesia for this procedure and is associated with a reduced requirement for inotropic support and improved efficiency.

Keywords: aortic stenosis; cardiology; conscious sedation; transcatheter aortic valve implantation.