Comparison of cone-beam computed tomography with multislice computed tomography in detection of small osseous condylar defects
- PMID: 27364215
- DOI: 10.1016/j.ajodo.2015.12.019
Comparison of cone-beam computed tomography with multislice computed tomography in detection of small osseous condylar defects
Abstract
Introduction: Previous studies have indicated that orthodontic-grade cone-beam computed tomography (CBCT) images are limited when displaying small defects at the mandibular condyles for diagnosis. In this study, we investigated whether this limitation was inherent to CBCT by comparing CBCT with multislice computed tomography (CT), and whether image segmentation and color mapping could overcome this limitation.
Methods: Nine fresh pig heads (18 condyles, 36 medial and lateral condylar regions) were used. Small osseous defects (diameter and depth, 1.5 mm) were created at the medial and lateral regions of the condyles shown by gutta percha markers. After the overlying soft tissues were restored, the pig heads underwent orthodontic-grade CBCT scans (0.4-mm voxel size; i-CAT; Imaging Sciences International, Hatfield, Pa) and medical-grade CT scans (0.625-mm voxel size; LightSpeed; GE, Little Chalfont, Buckinghamshire, United Kingdom). Subsequently, 2 calibrated and blinded raters diagnosed the defect numbers in each condylar region from CBCT and CT images using Dolphin 3D software (Patterson Supply, St Paul, Minn) without image segmentation, and then 1 week later with the proprietary image segmentation and color mapping tools of Dolphin 3D. Condylar polyvinyl siloxane impressions were collected and evaluated by the same raters to obtain physical diagnoses. Rediagnoses were made on randomly selected subsamples to assess reliability. Using the physical diagnoses as references, the accuracy of imaging diagnosis was assessed and statistically compared among the varied imaging and analysis methods.
Results: Image diagnoses of all imaging and analysis methods showed good or excellent intrarater and interrater reliability values, except for those of the segmented CBCT images, which were substantially lower. The numbers of overdiagnoses and underdiagnoses per condylar region were not significantly different among the varied imaging and analysis methods (Wilcoxon tests, P >0.05), but classification functions demonstrated substantially lower sensitivity and accuracy with CBCT than with CT. Logistic regression also showed that CT had a significantly higher probability (odds ratio, 2.4) than CBCT in reaching the correct diagnosis, whereas use of the image segmentation and color mapping tool proprietary to Dolphin 3D did not improve the diagnostic accuracy from CBCT images.
Conclusions: Even at a lower voxel size than medical CT images, orthodontic-grade CBCT images of mandibular condyles may be inherently less reliable and less accurate for the diagnosis of small condylar defects.
Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Evaluation of cone-beam computed tomography in the diagnosis of simulated small osseous defects in the mandibular condyle.Am J Orthod Dentofacial Orthop. 2014 Feb;145(2):143-56. doi: 10.1016/j.ajodo.2013.10.014. Am J Orthod Dentofacial Orthop. 2014. PMID: 24485728
-
Cone beam computed tomography-based models versus multislice spiral computed tomography-based models for assessing condylar morphology.Oral Surg Oral Med Oral Pathol Oral Radiol. 2016 Jan;121(1):96-105. doi: 10.1016/j.oooo.2015.10.015. Epub 2015 Oct 20. Oral Surg Oral Med Oral Pathol Oral Radiol. 2016. PMID: 26679363 Free PMC article.
-
Factors affecting the accuracy of buccal alveolar bone height measurements from cone-beam computed tomography images.Am J Orthod Dentofacial Orthop. 2013 Mar;143(3):353-63. doi: 10.1016/j.ajodo.2012.10.019. Am J Orthod Dentofacial Orthop. 2013. PMID: 23452969
-
Reliability and accuracy of segmentation of mandibular condyles from different three-dimensional imaging modalities: a systematic review.Dentomaxillofac Radiol. 2020 Jul;49(5):20190150. doi: 10.1259/dmfr.20190150. Epub 2019 Dec 3. Dentomaxillofac Radiol. 2020. PMID: 31778321 Free PMC article.
-
Three-dimensional cone beam computed tomography analysis protocols for condylar remodelling following orthognathic surgery: a systematic review.Int J Oral Maxillofac Surg. 2020 Feb;49(2):207-217. doi: 10.1016/j.ijom.2019.05.009. Epub 2019 Jun 17. Int J Oral Maxillofac Surg. 2020. PMID: 31221473
Cited by
-
Volumetric reconstruction and determination of minimum crosssectional area of the pharynx in patients with cleft lip and palate: comparison between two different softwares.J Appl Oral Sci. 2018 Oct 4;26:e20170282. doi: 10.1590/1678-7757-2017-0282. J Appl Oral Sci. 2018. PMID: 30304121 Free PMC article.
-
Influence of voxel size on the accuracy of linear measurements of the condyle in images of cone beam computed tomography: A pilot study.J Clin Exp Dent. 2018 Sep 1;10(9):e876-e882. doi: 10.4317/jced.54500. eCollection 2018 Sep. J Clin Exp Dent. 2018. PMID: 30386520 Free PMC article.
-
Development and validation of a clinical phantom reproducing various lesions for oral and maxillofacial radiology research.Imaging Sci Dent. 2023 Dec;53(4):345-353. doi: 10.5624/isd.20230129. Epub 2023 Sep 25. Imaging Sci Dent. 2023. PMID: 38174032 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous