Motion-insensitive carotid intraplaque hemorrhage imaging using 3D inversion recovery preparation stack of stars (IR-prep SOS) technique
- PMID: 27383756
- PMCID: PMC5441883
- DOI: 10.1002/jmri.25365
Motion-insensitive carotid intraplaque hemorrhage imaging using 3D inversion recovery preparation stack of stars (IR-prep SOS) technique
Abstract
Purpose: Carotid artery imaging is important in the clinical management of patients at risk for stroke. Carotid intraplaque hemorrhage (IPH) presents an important diagnostic challenge. 3D magnetization prepared rapid acquisition gradient echo (MPRAGE) has been shown to accurately image carotid IPH; however, this sequence can be limited due to motion- and flow-related artifact. The purpose of this work was to develop and evaluate an improved 3D carotid MPRAGE sequence for IPH detection. We hypothesized that a radial-based k-space trajectory sequence such as "Stack of Stars" (SOS) incorporated with inversion recovery preparation would offer reduced motion sensitivity and more robust flow suppression by oversampling of central k-space.
Materials and methods: A total of 31 patients with carotid disease (62 carotid arteries) were imaged at 3T magnetic resonance imaging (MRI) with 3D IR-prep Cartesian and SOS sequences. Image quality was determined between SOS and Cartesian MPRAGE in 62 carotid arteries using t-tests and multivariable linear regression. Kappa analysis was used to determine interrater reliability.
Results: In all, 25 among 62 carotid plaques had carotid IPH by consensus from the reviewers on SOS compared to 24 on Cartesian sequence. Image quality was significantly higher with SOS compared to Cartesian (mean 3.74 vs. 3.11, P < 0.001). SOS acquisition yielded sharper image features with less motion (19.4% vs. 45.2%, P < 0.002) and flow artifact (27.4% vs. 41.9%, P < 0.089). There was also excellent interrater reliability with SOS (kappa = 0.89), higher than that of Cartesian (kappa = 0.84).
Conclusion: By minimizing flow and motion artifacts and retaining high interrater reliability, the SOS MPRAGE has important advantages over Cartesian MPRAGE in carotid IPH detection.
Level of evidence: 1 J. Magn. Reson. Imaging 2017;45:410-417.
Keywords: IPH; MPRAGE; SOS; carotid plaque; flow suppression; stroke.
© 2016 International Society for Magnetic Resonance in Medicine.
Figures




Similar articles
-
Magnetic Resonance Imaging Detection of Intraplaque Hemorrhage.Magn Reson Insights. 2017 Mar 7;10:1-8. doi: 10.1177/1178623X17694150. eCollection 2017. Magn Reson Insights. 2017. PMID: 28469441 Free PMC article. Review.
-
Differentiation of symptomatic and asymptomatic carotid intraplaque hemorrhage using 3D high-resolution diffusion-weighted stack of stars imaging.NMR Biomed. 2021 Nov;34(11):e4582. doi: 10.1002/nbm.4582. Epub 2021 Jul 23. NMR Biomed. 2021. PMID: 34296793
-
Carotid Intraplaque Hemorrhage Imaging with Quantitative Vessel Wall T1 Mapping: Technical Development and Initial Experience.Radiology. 2018 Apr;287(1):276-284. doi: 10.1148/radiol.2017170526. Epub 2017 Nov 8. Radiology. 2018. PMID: 29117484 Free PMC article.
-
An optimized 3D spoiled gradient recalled echo pulse sequence for hemorrhage assessment using inversion recovery and multiple echoes (3D SHINE) for carotid plaque imaging.Magn Reson Med. 2010 Nov;64(5):1341-51. doi: 10.1002/mrm.22517. Magn Reson Med. 2010. PMID: 20574968
-
Pitfalls in liver MRI: Technical approach to avoiding misdiagnosis and improving image quality.J Magn Reson Imaging. 2019 Jan;49(1):41-58. doi: 10.1002/jmri.26343. Epub 2018 Oct 8. J Magn Reson Imaging. 2019. PMID: 30295343 Review.
Cited by
-
Magnetization-prepared GRASP MRI for rapid 3D T1 mapping and fat/water-separated T1 mapping.Magn Reson Med. 2021 Jul;86(1):97-114. doi: 10.1002/mrm.28679. Epub 2021 Feb 13. Magn Reson Med. 2021. PMID: 33580909 Free PMC article.
-
Advanced targeted nanomedicines for vulnerable atherosclerosis plaque imaging and their potential clinical implications.Front Pharmacol. 2022 Oct 13;13:906512. doi: 10.3389/fphar.2022.906512. eCollection 2022. Front Pharmacol. 2022. PMID: 36313319 Free PMC article. Review.
-
Magnetic Resonance Imaging Detection of Intraplaque Hemorrhage.Magn Reson Insights. 2017 Mar 7;10:1-8. doi: 10.1177/1178623X17694150. eCollection 2017. Magn Reson Insights. 2017. PMID: 28469441 Free PMC article. Review.
-
Surveillance of abdominal aortic aneurysm using accelerated 3D non-contrast black-blood cardiovascular magnetic resonance with compressed sensing (CS-DANTE-SPACE).J Cardiovasc Magn Reson. 2019 Oct 28;21(1):66. doi: 10.1186/s12968-019-0571-2. J Cardiovasc Magn Reson. 2019. PMID: 31660983 Free PMC article.
-
Carotid plaque imaging and the risk of atherosclerotic cardiovascular disease.Cardiovasc Diagn Ther. 2020 Aug;10(4):1048-1067. doi: 10.21037/cdt.2020.03.10. Cardiovasc Diagn Ther. 2020. PMID: 32968660 Free PMC article. Review.
References
-
- Cai JM, Hatsukami TS, Ferguson MS, Small R, Polissar NL, Yuan C. Classification of human carotid atherosclerotic lesions with in vivo multicontrast magnetic resonance imaging. Circulation. 2002;106:1368–1373. - PubMed
-
- Cappendijk VC, Cleutjens KB, Kessels AG, et al. Assessment of human atherosclerotic carotid plaque components with multisequence MR imaging: initial experience. Radiology. 2005;234:487–492. - PubMed
-
- Hatsukami L, Ross R, Polissar N, et al. Visualization of fibrous cap thickness and rupture in human atherosclerotic carotid plaque in vivo with high-resolution magnetic resonance imaging. Ciculation. 2000;102:959–964. - PubMed
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials
Miscellaneous