Abstract

Histories of mold, pollen, dust, food, chemicals, and electromagnetic field (EMF) sensitivities are the major categories of triggers for chemical sensitivity. They are tied together by the coherence phenomenon, where each has its own frequencies and identifiable EMF; therefore, they can be correlated. The diagnosis of chemical sensitivity can be done accurately in a less-polluted, controlled environment, as was done in these studies. The principles of diagnosis and treatment depend on total environmental and total body pollutant loads, masking or adaptation, bipolarity of response, and biochemical individuality, among others. These principles make less-polluted, controlled conditions necessary. The clinician has to use less-polluted water and organic food with individual challenges for testing, including dust, mold, pesticide, natural gas, formaldehyde, particulates, and EMF testing, which needs to be performed in less-polluted copper-screened rooms. The challenge tests for proof of chemical sensitivity include inhaled toxics within a clean booth that is chemical- and particulate-free at ambient doses in parts per million (ppm) or parts per billion (ppb). Individual foods, both organic and commercial (that are contaminated with herbicides and pesticides), are used orally. Water testing and intradermal testing are performed in a less-polluted, controlled environment. These include specific dose injections of molds, dust, and pollen that are preservative-free, individual organic foods, and individual chemicals, i.e. methane, ethane, propane, butane, hexane, formaldehyde, ethanol, car exhaust, jet fuel exhaust, and prosthetic implants (metal plates, pacemakers, mesh, etc.). Normal saline is used as a placebo. EMF testing is performed in a copper-screened room using a frequency generator. In our experience, 80% of the EMF-sensitive patients had chemical sensitivity when studied under less-polluted conditions for particulates, controlled natural gas, pesticides, and chemicals like formaldehyde.

PubMed Disclaimer

MeSH terms

LinkOut - more resources