Validation study of arm positions for evaluation of global spinal balance in EOS imaging
- PMID: 27388212
- DOI: 10.1007/s00590-016-1813-8
Validation study of arm positions for evaluation of global spinal balance in EOS imaging
Abstract
Background: The sagittal vertical axis (SVA) is important in the evaluation of spinal sagittal balance. Although the "fists-on-clavicles" (FOC) position has been widely used in radiographic examinations, it does not define shoulder flexion in detail. Meanwhile, in EOS imaging, the "hands-on-cheeks" (HOC) position is widely used but has not been well investigated. The purpose of this study was to investigate the relative usefulness of FOC and HOC in investigating SVA.
Materials and methods: Mean SVA was measured by EOS imaging using standing lateral radiographs of 34 volunteers in four different positions: relaxed (RLX), shoulder flexion at 90° with FOC (FOC90), elbows touching the trunk with FOC (FOCET), and HOC.
Results: The mean SVA was 2.0 ± 2.1 cm in RLX; -1.4 ± 3.2 cm in FOC90; -0.5 ± 3.0 cm in FOCET; and -0.2 ± 2.9 cm in HOC. The negative shift from RLX was significantly greater in FOC90 than in FOCET (-3.4 ± 2.2 vs -2.5 ± 2.4 cm; p = 0.0182). The negative shift from RLX in HOC was almost equal to that in FOCET; the difference was 0.3 cm (-2.2 ± 2.2 vs -2.5 ± 2.4 cm; p = 0.2560).
Conclusion: FOC90 showed a negative SVA shift in comparison with FOCET. The difference in the mean SVA between HOC and FOCET was 0.3 cm, a clinically small difference.
Keywords: Arm position; EOS imaging; Fists-on-clavicles; Hands-on-cheeks; Lateral radiographic evaluation; Sagittal vertical axis.
Similar articles
-
Optimal arm position for evaluation of spinal sagittal balance.J Spinal Disord Tech. 2011 Apr;24(2):105-9. doi: 10.1097/BSD.0b013e3181da36c4. J Spinal Disord Tech. 2011. PMID: 21445023
-
Does the fists-on-clavicles position represent a functional standing position?Spine (Phila Pa 1976). 2009 Apr 15;34(8):808-12. doi: 10.1097/BRS.0b013e31819e2191. Spine (Phila Pa 1976). 2009. PMID: 19365249
-
Which lateral radiographic positioning technique provides the most reliable and functional representation of a patient's sagittal balance?Spine (Phila Pa 1976). 2009 Apr 20;34(9):949-54. doi: 10.1097/BRS.0b013e318199650a. Spine (Phila Pa 1976). 2009. PMID: 19532003 Clinical Trial.
-
Standing lateral radiographic positioning does not represent customary standing balance.Spine (Phila Pa 1976). 2003 Jun 1;28(11):1176-82. doi: 10.1097/01.BRS.0000067271.00258.51. Spine (Phila Pa 1976). 2003. PMID: 12782989 Clinical Trial.
-
[Sagittal Balance of the Spine--Clinical Importance and Radiographic Assessment].Z Orthop Unfall. 2016 Apr;154(2):128-33. doi: 10.1055/s-0041-109327. Epub 2015 Dec 15. Z Orthop Unfall. 2016. PMID: 26670303 Review. German.
Cited by
-
The effect of arm positions used during radiography on spinal alignment parameters assessed by 3D ultrasound imaging in adolescents with and volunteers without idiopathic scoliosis.Eur Spine J. 2025 Feb;34(2):578-592. doi: 10.1007/s00586-025-08650-1. Epub 2025 Jan 11. Eur Spine J. 2025. PMID: 39799270
-
How do different standing positions affect trunk muscle activation in LBP-developers during prolonged standing?BMC Musculoskelet Disord. 2025 Mar 26;26(1):299. doi: 10.1186/s12891-025-08525-y. BMC Musculoskelet Disord. 2025. PMID: 40140795 Free PMC article. Clinical Trial.
-
Does the positioning of the patient in the EOS machine affect the validity of cervical and head parameters calculated on whole-spine radiographs?Medicine (Baltimore). 2024 Nov 8;103(45):e40422. doi: 10.1097/MD.0000000000040422. Medicine (Baltimore). 2024. PMID: 39533602 Free PMC article.
-
The impact of different standing positions on gluteus medius activation and lumbar lordosis in LBP-developers during prolonged standing.PLoS One. 2025 Feb 11;20(2):e0317291. doi: 10.1371/journal.pone.0317291. eCollection 2025. PLoS One. 2025. PMID: 39932988 Free PMC article.
-
Comparison of Whole Spine Sagittal Alignment in Patients with Spinal Disease between EOS Imaging System versus Conventional Whole Spine X-ray.Yonsei Med J. 2022 Nov;63(11):1027-1034. doi: 10.3349/ymj.2022.0023. Yonsei Med J. 2022. PMID: 36303311 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources