Abstract
Background: Intravascular ultrasound detects stent edge dissections after percutaneous coronary intervention that are not seen angiographically. This study investigated the association between stent edge dissections and clinical outcomes.
Methods and results: ADAPT-DES (Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents) was a large-scale, prospective, multicenter study of patients undergoing drug-eluting stent implantation. In this prospective substudy, 2062 patients (2433 lesions) were evaluated with intravascular ultrasound to characterize the morphological features and clinical outcomes of stent edge dissection after percutaneous coronary intervention. The prevalence of post-percutaneous coronary intervention stent edge dissection was 6.6% per lesion (161 of 2433). Calcified plaque at the proximal stent edge (relative risk [RR]=1.72; P=0.04) and proximal stent edge expansion (RR=1.18; P=0.004) were predictors for proximal dissection; attenuated plaque at the distal stent edge (RR=3.52; P=0.004), distal reference plaque burden (RR=1.56; P<0.0001), and distal edge stent expansion (RR=1.11; P=0.02) were predictors for distal dissection. At 1-year follow-up, target lesion revascularization was more common in lesions with versus without dissection (5.2% versus 2.7%; P=0.04). Multivariable analysis indicated that residual dissection was associated with target lesion revascularization at 1-year follow-up (RR=2.67; P=0.02). Among lesions with dissection, smaller effective lumen area increased the risk of target lesion revascularization at 1-year follow-up (cutoff value of 5.1 mm(2); P=0.05).
Conclusions: Greater stent expansion and the presence of large, calcified, and/or attenuated plaques were independent predictors of stent edge dissection. Residual stent edge dissection, especially with a smaller effective lumen area, was associated with target lesion revascularization during 1-year follow-up after drug-eluting stent implantation.
Clinical trial registration: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00638794.
Keywords: angiography; dissection; drug-eluting stent; prevalence; stent.
© 2016 American Heart Association, Inc.
Similar articles
-
Predictors and Long-Term Clinical Impact of Acute Stent Malapposition: An Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents (ADAPT-DES) Intravascular Ultrasound Substudy.J Am Heart Assoc. 2016 Dec 22;5(12):e004438. doi: 10.1161/JAHA.116.004438. J Am Heart Assoc. 2016. PMID: 28007741 Free PMC article.
-
Prevalence and Clinical Impact of Tissue Protrusion After Stent Implantation: An ADAPT-DES Intravascular Ultrasound Substudy.JACC Cardiovasc Interv. 2016 Jul 25;9(14):1499-507. doi: 10.1016/j.jcin.2016.05.043. JACC Cardiovasc Interv. 2016. PMID: 27478119
-
Effect of obesity on coronary atherosclerosis and outcomes of percutaneous coronary intervention: grayscale and virtual histology intravascular ultrasound substudy of assessment of dual antiplatelet therapy with drug-eluting stents.Circ Cardiovasc Interv. 2014 Dec 31;8(1):e001392. doi: 10.1161/CIRCINTERVENTIONS.114.001392. Print 2015 Jan. Circ Cardiovasc Interv. 2014. PMID: 25552564 Clinical Trial.
-
The Role of Vascular Imaging in Guiding Routine Percutaneous Coronary Interventions: A Meta-Analysis of Bare Metal Stent and Drug-Eluting Stent Trials.Cardiovasc Ther. 2015 Dec;33(6):360-6. doi: 10.1111/1755-5922.12160. Cardiovasc Ther. 2015. PMID: 26363283 Review.
-
Edge vascular response after percutaneous coronary intervention: an intracoronary ultrasound and optical coherence tomography appraisal: from radioactive platforms to first- and second-generation drug-eluting stents and bioresorbable scaffolds.JACC Cardiovasc Interv. 2013 Mar;6(3):211-21. doi: 10.1016/j.jcin.2013.01.132. JACC Cardiovasc Interv. 2013. PMID: 23517830 Review.
Cited by
-
Optical Coherence Tomography of the Coronary Arteries.Int J Angiol. 2021 Mar;30(1):29-39. doi: 10.1055/s-0041-1724019. Epub 2021 Feb 12. Int J Angiol. 2021. PMID: 34045841 Free PMC article. Review.
-
Outcomes of optical coherence tomography compared with intravascular ultrasound and with angiography to guide coronary stent implantation: one-year results from the ILUMIEN III: OPTIMIZE PCI trial.EuroIntervention. 2021 Jan 20;16(13):1085-1091. doi: 10.4244/EIJ-D-20-00498. EuroIntervention. 2021. PMID: 32540793 Free PMC article. Clinical Trial.
-
2023 Guidelines of the Taiwan Society of Cardiology on the Diagnosis and Management of Chronic Coronary Syndrome.Acta Cardiol Sin. 2023 Jan;39(1):4-96. doi: 10.6515/ACS.202301_39(1).20221103A. Acta Cardiol Sin. 2023. PMID: 36685161 Free PMC article.
-
Intravascular ultrasound assessment of stent edge restenosis mechanisms and treatment outcomes following percutaneous coronary intervention.Sci Rep. 2025 May 10;15(1):16298. doi: 10.1038/s41598-025-01381-9. Sci Rep. 2025. PMID: 40348838 Free PMC article.
-
Intravascular ultrasound-factors associated with slow flow following rotational atherectomy in heavily calcified coronary artery.Sci Rep. 2022 Apr 5;12(1):5674. doi: 10.1038/s41598-022-09585-z. Sci Rep. 2022. PMID: 35383228 Free PMC article.
Publication types
MeSH terms
Associated data
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical