Multiple breath washout of hyperpolarized 129 Xe and 3 He in human lungs with three-dimensional balanced steady-state free-precession imaging
- PMID: 27404992
- PMCID: PMC5484367
- DOI: 10.1002/mrm.26319
Multiple breath washout of hyperpolarized 129 Xe and 3 He in human lungs with three-dimensional balanced steady-state free-precession imaging
Abstract
Purpose: To compare quantitative fractional ventilation measurements from multiple breath washout imaging (MBW-I) using hyperpolarized 3 He with both spoiled gradient echo (SPGR) and balanced steady-state free precession (bSSFP) three-dimensional (3D) pulse sequences and to evaluate the feasibility of MBW-I with hyperpolarized 129 Xe.
Methods: Seven healthy subjects were scanned using 3 He MBW-I with 3D SPGR and bSSFP sequences. Five also underwent MBW-I with 129 Xe. A dual-tuned coil was used to acquire MBW-I data from both nuclei in the same subject position, enabling direct comparison of regional information.
Results: High-quality MBW images were obtained with bSSFP sequences using a reduced dose (100 mL) of inhaled hyperpolarized 3 He. 3D MBW-I with 129 Xe was also successfully demonstrated with a bSSFP sequence. Regional quantitative ventilation measures derived from 3 He and 129 Xe MBW-I correlated well in all subjects (P < 0.001) with mean Pearson's correlation coefficients of r = 0.61 and r = 0.52 for 3 He SPGR-bSSFP and 129 Xe-3 He (bSSFP) comparisons. The average intersubject mean difference (and standard deviation) in fractional ventilation in SPGR-bSSFP and 129 Xe-3 He comparisons was 15% (28%) and 9% (38%), respectively.
Conclusions: Improved sensitivity in MBW-I can be achieved with polarization-efficient bSSFP sequences. Same scan-session 3D MBW-I with 3 He and 129 Xe has been demonstrated using a dual-tuned coil. Magn Reson Med 77:2288-2295, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
Keywords: 129Xe; 3He; hyperpolarized gas; lung function; multiple breath washout.
© 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.
Figures
References
-
- Robinson PD, Goldman MD, Gustafsson PM. Inert gas washout: theoretical background and clinical utility in respiratory disease. Respiration 2009;78:339–355. - PubMed
-
- Horsley AR, Gustafsson PM, Macleod KA, Saunders C, Greening AP, Porteous DJ, Davies JC, Cunningham S, Alton EWFW, Innes JA. Lung clearance index is a sensitive, repeatable and practical measure of airways disease in adults with cystic fibrosis. Thorax 2008;63:135–140. - PubMed
-
- Gustafsson PM, De Jong PA, Tiddens HA, Lindblad A. Multiple‐breath inert gas washout and spirometry versus structural lung disease in cystic fibrosis. Thorax 2008;63:129–134. - PubMed
-
- Verbanck S, Schuermans D, Meysman M, Paiva M, Vincken W. Noninvasive assessment of airway alterations in smokers: the small airways revisited. Am J Respir Crit Care Med 2004;170:414–419. - PubMed
-
- Verbanck S, Schuermans D, Van Muylem A, Melot C, Noppen M, Vincken W, Paiva M. Conductive and acinar lung‐zone contributions to ventilation inhomogeneity in COPD. Am J Respir Crit Care Med 1998;157:1573–1577. - PubMed
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
