. 2016 Jun 29;13(4):282-284.
doi: 10.1016/j.jor.2016.06.018. eCollection 2016 Dec.

Noise production in ceramic-on-ceramic total hip arthroplasty is associated with lower patient satisfaction and hip scores

Affiliations

Noise production in ceramic-on-ceramic total hip arthroplasty is associated with lower patient satisfaction and hip scores

James A Gillespie et al. J Orthop. .

Abstract

Background: Ceramic-on-ceramic total hip arthroplasties (THA) are commonly implanted. We investigated the incidence of noise in ceramic-on-ceramic and determined any association with patient satisfaction and hip scores.

Methods: We recruited 140 THA. Questionnaires were completed to assess the incidence and frequency of noise, and satisfaction level. Hip and SF-12 scores were recorded.

Results: Forty-two patients (30%) were aware of noise production. Patients with noise production had lower satisfaction, mean hip and SF-12 scores than those with silent hips.

Conclusion: Given the high incidence of noise in ceramic-on-ceramic THA, patients should be counselled on this risk pre-operatively.

Keywords: Ceramic; Noise; Squeak; Total hip arthroplasty.

PubMed Disclaimer

Figures

Fig. 1
Fig. 1
WOMAC, Oxford Hip and SF-12 scores were significantly lower in patients who reported noise from their THA.

References

    1. Sedel L. Evolution of alumina-on-alumina implants: a review. Clin Orthop Relat Res. 2000;379:48–54. - PubMed
    1. Schroder D., Bornstein L., Bostrom M.P.G., Nestor B.J., Padgett D.E., Westrich G.H. Ceramic-on-ceramic total hip arthroplasty: incidence of instability and noise. Clin Orthop Relat Res. 2011;469:437–442. - PMC - PubMed
    1. Jarrett C.A., Ranawat A.S., Bruzzone M., Blum Y.C., Rodriguez J.A., Ranawat C.S. The squeaking hip: a phenomenon of ceramic-on-ceramic total hip arthroplasty. J Bone Jt Surg Am. 2009;91:1344–1349. - PubMed
    1. Lusty P.J., Tai C.C., Sew-Hoy R.P., Walter W.L., Walter W.K., Zicat B.A. Third-generation alumina-on-alumina ceramic bearings in cementless total hip arthroplasty. J Bone Jt Surg Am. 2007;89:2676–2683. - PubMed
    1. Mai K., Verioti C., Ezzet K.A., Copp S.N., Walker R.H., Colwell C.W. Incidence of ‘squeaking’ after ceramic-on-ceramic total hip arthroplasty. Clin Orthop Relat Res. 2010;468:413–417. - PMC - PubMed