Abstract
Background: Ceramic-on-ceramic total hip arthroplasties (THA) are commonly implanted. We investigated the incidence of noise in ceramic-on-ceramic and determined any association with patient satisfaction and hip scores.
Methods: We recruited 140 THA. Questionnaires were completed to assess the incidence and frequency of noise, and satisfaction level. Hip and SF-12 scores were recorded.
Results: Forty-two patients (30%) were aware of noise production. Patients with noise production had lower satisfaction, mean hip and SF-12 scores than those with silent hips.
Conclusion: Given the high incidence of noise in ceramic-on-ceramic THA, patients should be counselled on this risk pre-operatively.
Keywords: Ceramic; Noise; Squeak; Total hip arthroplasty.
© 2016 Prof. PK Surendran Memorial Education Foundation. Published by Elsevier, a division of Reed Elsevier India, Pvt. Ltd. All rights reserved.
Figures
References
-
- Sedel L. Evolution of alumina-on-alumina implants: a review. Clin Orthop Relat Res. 2000;379:48–54. - PubMed
-
- Jarrett C.A., Ranawat A.S., Bruzzone M., Blum Y.C., Rodriguez J.A., Ranawat C.S. The squeaking hip: a phenomenon of ceramic-on-ceramic total hip arthroplasty. J Bone Jt Surg Am. 2009;91:1344–1349. - PubMed
-
- Lusty P.J., Tai C.C., Sew-Hoy R.P., Walter W.L., Walter W.K., Zicat B.A. Third-generation alumina-on-alumina ceramic bearings in cementless total hip arthroplasty. J Bone Jt Surg Am. 2007;89:2676–2683. - PubMed
LinkOut - more resources
Full Text Sources
Other Literature Sources