The validity and reliability of continuous-wave near-infrared spectroscopy for the assessment of leg blood volume during an orthostatic challenge
- PMID: 27415611
- DOI: 10.1016/j.atherosclerosis.2016.06.030
The validity and reliability of continuous-wave near-infrared spectroscopy for the assessment of leg blood volume during an orthostatic challenge
Abstract
Near-infrared spectroscopy (NIRS) can potentially be used to assess the cardiovascular autonomic system by monitoring orthostatic challenge-induced shifts in lower limb blood volume. However, in order to be of clinical utility the test must be valid, reliable, and relatively simple to conduct.
Purpose: To induce lower limb blood volume shifts using a 10 min 70° head-up tilt, and: (1) in the soleus, determine the validity of an inexpensive continuous wave (cw)-NIRS device by comparing to a criterion frequency-domain (fd-) NIRS device, (2) determine the between-day reliability of soleus assessments obtained from cw-NIRS and fd-NIRS; and, (3) compare the between-day reliability for fd-NIRS assessments obtained at the soleus (standard) and gastrocnemius (simpler alternative).
Methods: Fifteen non-smoking healthy adults were tested on 3 different mornings, under standardized conditions, separated by a maximum of 7 days. Total haemoglobin concentration (tHb) was continuously monitored bi-laterally in the medial soleus using cw-NIRS and fd-NIRS. For site comparison, tHb was measured in the medial gastrocnemius using fd-NIRS.
Results: (1) The area under the curve (AUC) for cw-NIRS and fd-NIRS assessments at the soleus were not significantly different (p = 0.619). (2) The criterion (0.75) intra-class correlation coefficient (ICC) was exceeded for both cw-NIRS and fd-NIRS. (3) The criterion ICC was exceeded for both soleus and gastrocnemius assessments.
Conclusion: Continuous-wave NIRS can be used to monitor orthostatic stress-induced shifts in lower leg blood volume with acceptable validity and reliability. This orthostatic test may present a relatively simple and inexpensive approach for assessing the cardiovascular autonomic nervous system.
Keywords: Autonomic function; Frequency-domain spectroscopy; Head-up tilt.
Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Similar articles
-
Frequency-domain vs continuous-wave near-infrared spectroscopy devices: a comparison of clinically viable monitors in controlled hypoxia.J Clin Monit Comput. 2017 Oct;31(5):967-974. doi: 10.1007/s10877-016-9942-5. Epub 2016 Oct 24. J Clin Monit Comput. 2017. PMID: 27778208 Free PMC article.
-
Comparison of frequency-domain and continuous-wave near-infrared spectroscopy devices during the immediate transition.BMC Pediatr. 2020 Feb 28;20(1):94. doi: 10.1186/s12887-020-1987-4. BMC Pediatr. 2020. PMID: 32111176 Free PMC article.
-
Orthostatic leg blood volume changes assessed by near-infrared spectroscopy.Exp Physiol. 2012 Mar;97(3):353-61. doi: 10.1113/expphysiol.2011.061051. Epub 2011 Nov 16. Exp Physiol. 2012. PMID: 22090063
-
The use of near-infrared spectroscopy in understanding skeletal muscle physiology: recent developments.Philos Trans A Math Phys Eng Sci. 2011 Nov 28;369(1955):4577-90. doi: 10.1098/rsta.2011.0230. Philos Trans A Math Phys Eng Sci. 2011. PMID: 22006907 Review.
-
Frequency-Domain Techniques for Cerebral and Functional Near-Infrared Spectroscopy.Front Neurosci. 2020 Apr 7;14:300. doi: 10.3389/fnins.2020.00300. eCollection 2020. Front Neurosci. 2020. PMID: 32317921 Free PMC article. Review.
Cited by
-
A Primer on Repeated Sitting Exposure and the Cardiovascular System: Considerations for Study Design, Analysis, Interpretation, and Translation.Front Cardiovasc Med. 2021 Aug 17;8:716938. doi: 10.3389/fcvm.2021.716938. eCollection 2021. Front Cardiovasc Med. 2021. PMID: 34485414 Free PMC article. Review.
-
The effect of cardiorespiratory fitness and habitual physical activity on cardiovascular responses to 2 h of uninterrupted sitting.J Appl Physiol (1985). 2024 May 1;136(5):1087-1096. doi: 10.1152/japplphysiol.00361.2023. Epub 2024 Mar 14. J Appl Physiol (1985). 2024. PMID: 38482575 Free PMC article.
-
Prefrontal hemodynamic changes measured using near-infrared spectroscopy during the Valsalva maneuver in patients with orthostatic intolerance.Neurophotonics. 2018 Jan;5(1):015002. doi: 10.1117/1.NPh.5.1.015002. Epub 2018 Jan 26. Neurophotonics. 2018. PMID: 29392157 Free PMC article.
-
Evaluation of Tibial Hemodynamic Response to Glucose Tolerance Test in Young Healthy Males and Females.Nutrients. 2023 Sep 20;15(18):4062. doi: 10.3390/nu15184062. Nutrients. 2023. PMID: 37764845 Free PMC article.
-
Pulse-wave velocity assessments derived from a simple photoplethysmography device: Agreement with a referent device.Front Cardiovasc Med. 2023 Feb 7;10:1108219. doi: 10.3389/fcvm.2023.1108219. eCollection 2023. Front Cardiovasc Med. 2023. PMID: 36824455 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources