Xenon computed tomography measuring cerebral blood flow in the determination of brain death in children
- PMID: 2742357
- DOI: 10.1002/ana.410250603
Xenon computed tomography measuring cerebral blood flow in the determination of brain death in children
Abstract
Local cerebral blood flow was measured using stable xenon computed tomography in 21 children, 10 of whom were clinically brain dead and had electrocerebral silence as determined by electroencephalography. Radioisotopic brain scanning in 9 patients showed no visible cerebral activity in all patients and minimal residual sagittal sinus activity in 4. In this population, mean cerebral blood flow as measured by xenon computed tomography was 1.3 +/- 1.6 ml/min/100 gm. Respiratory support was discontinued in 8 patients, and 2 patients had cardiac arrest. Eleven profoundly comatose children who did not meet all clinical criteria for brain death and who had markedly suppressed but not isoelectric electroencephalograms had an average cerebral blood flow of 33.5 +/- 16.3 ml/min/100 gm. There was no difference in cerebral blood flow in those children who survived (30.4 +/- 16.3 ml/min/100 gm; n = 7) compared with those who died acutely (38.3 +/- 14.3 ml/min/100 gm; n = 4). Two patients who survived had average total flows of only 11.8 and 12.1 ml/min/100 gm. Our findings suggest that in infants and children older than 1 month, (1) cerebral blood flow below approximately 10 ml/min/100 gm is consistent with clinical brain death, (2) cerebral blood flow of less than 5 ml/min/100 gm is consistent with no flow as demonstrated by radionuclide techniques, and (3) flow of more than 10 to 15 ml/min/100 gm is associated with the potential for survival.
Similar articles
-
Failure of electroencephalography to diagnose brain death in comatose children.Ann Neurol. 1979 Dec;6(6):512-7. doi: 10.1002/ana.410060609. Ann Neurol. 1979. PMID: 394669
-
Declaring pediatric brain death: current practice in a Canadian pediatric critical care unit.CMAJ. 1995 Oct 1;153(7):909-16. CMAJ. 1995. PMID: 7553492 Free PMC article.
-
Cerebral hemodynamic and metabolic changes in fulminant hepatic failure: a retrospective study.Hepatology. 1994 Jan;19(1):80-7. Hepatology. 1994. PMID: 8276371
-
The case against confirmatory tests for determining brain death in adults.Neurology. 2010 Jul 6;75(1):77-83. doi: 10.1212/WNL.0b013e3181e62194. Neurology. 2010. PMID: 20603486 Review.
-
Brain death in children: Part II.Pediatr Neurol. 1987 Mar-Apr;3(2):69-77. doi: 10.1016/0887-8994(87)90030-0. Pediatr Neurol. 1987. PMID: 3334011 Review.
Cited by
-
Current and future therapies of pediatric cardiopulmonary arrest.Indian J Pediatr. 2008 Jun;75(6):609-14. doi: 10.1007/s12098-008-0117-3. Epub 2008 Aug 31. Indian J Pediatr. 2008. PMID: 18759090 Free PMC article. Review.
-
Accuracy of Computed Tomographic Perfusion in Diagnosis of Brain Death: A Prospective Cohort Study.Med Sci Monit. 2018 May 4;24:2777-2785. doi: 10.12659/MSM.906304. Med Sci Monit. 2018. PMID: 29727439 Free PMC article.
-
Establishing brain death: the potential role of nuclear medicine in the search for a reliable confirmatory test.Eur J Nucl Med. 1991;18(2):75-7. doi: 10.1007/BF00950749. Eur J Nucl Med. 1991. PMID: 2044575 No abstract available.
-
Cerebral blood flow in the newborn infant.Arch Dis Child Fetal Neonatal Ed. 1996 Jan;74(1):F63-9. doi: 10.1136/fn.74.1.f63. Arch Dis Child Fetal Neonatal Ed. 1996. PMID: 8653440 Free PMC article. Review.
-
High-Fidelity MRI Assessment of Cerebral Perfusion in Healthy Neonates Less Than 1 Week of Age.J Magn Reson Imaging. 2025 Sep;62(3):737-748. doi: 10.1002/jmri.29740. Epub 2025 Feb 13. J Magn Reson Imaging. 2025. PMID: 39945520
MeSH terms
Substances
LinkOut - more resources
Full Text Sources