Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 Spring;10(2):99-105.
doi: 10.15171/joddd.2016.016. Epub 2016 Jun 15.

Effects of Orthokin, Sensikin and Persica mouth rinses on the force degradation of elastic chains and NiTi coil springs

Affiliations

Effects of Orthokin, Sensikin and Persica mouth rinses on the force degradation of elastic chains and NiTi coil springs

Zahra Javanmardi et al. J Dent Res Dent Clin Dent Prospects. 2016 Spring.

Abstract

Background. Elastomeric chains and NiTi coil springs are two major traction aids in orthodontic tooth movements. Force degradation occurs over time in both groups, with higher percentages in elastic chains. The effects of environmental factors and some mouth rinses on this force decay have been previously studied. No study has been performed to evaluate the effect of current popular mouth rinses such as Orthokin, Sensikin and Persica on this force degradation. Methods . Forty pieces of elastic chains consisting of 5 loops (Ortho Technology, USA) and 40 NiTi closed coil springs (3M Unitek, Germany) were divided into 4 groups: control (artificial saliva), Orthokin mouthwash, Sensikin mouthwash and Persica mouthwash. All the groups were kept in an incubator at 37°C for 3 weeks. In the test groups, the samples were immersed in mouthwash twice a day. Force degradation was measured at 5 time intervals: baseline, 1 hour, 24 hours, 1 week and 3 weeks, using a digital force gauge. Repeated-measures ANOVA and one-way ANOVA were used for statistical analysis. Results. Force decay occurred over time in both elastic chainand coil spring groups. In elastic chain group, after 3 weeks, Orthokin mouth rinse had significantly lower force degradation compared to other groups (P < 0.05) and in coil spring group there were no statistically significant differences in force degradation after 3 weeks between the subgroups (P > 0.05). Conclusion. Based the results of this study, these three mouthwashes did not increase the force degradation of orthodontic traction aids under study.

Keywords: Elastomeric chain; NiTi coil spring; force degradation; mouth rinse.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Figure 2
Figure 2
Figure 3
Figure 3

Similar articles

Cited by

References

    1. Halimi A, Azeroual MF, Doukkali A, El Mabrouk K, Zaoui F. Elastomeric chain force decay in artificial saliva: An in vitro study. Int Orthod. 2013;11:60–70. doi: 10.1016/j.ortho.2012.12.007. - DOI - PubMed
    1. Baty DL, Storie DJ, von Fraunhofer JA. Synthetic elastomeric chains: A literature review. Am J Orthod Dentofacial Orthop. 1994;105:536–42. doi: 10.1016/S0889-5406(94)70137-7. - DOI - PubMed
    1. Larrabee TM, Liu SS, Torres-Gorena A, Soto-Rojas A, Eckert GJ, Stewart KT. The effects of varying alcohol concentrations commonly found in mouth rinses on the force decay of elastomeric chain. Angle Orthod. 2012;82:894–9. doi: 10.2319/062211-407.1. - DOI - PMC - PubMed
    1. Mirhashemi A, Saffarshahroudi A, Sodagar A, Atai M. Force-degradation pattern of six different orthodontic elastomeric chains. J Dent (Tehran) 2012;9:204–15. - PMC - PubMed
    1. Kochenborger C, Lopes da Saliva D, Marchioro EM, Vargas DA, Hahn L. Assessment of force decay in orthodontic elastomeric chains: an in vitro study. Dental Press J Orthod. 2011;16:93–9.

LinkOut - more resources