Ultrasonographic Measures of the Acromiohumeral Distance and Supraspinatus Tendon Thickness in Manual Wheelchair Users With Spinal Cord Injury
- PMID: 27431359
- DOI: 10.1016/j.apmr.2016.06.018
Ultrasonographic Measures of the Acromiohumeral Distance and Supraspinatus Tendon Thickness in Manual Wheelchair Users With Spinal Cord Injury
Abstract
Objectives: (1) To evaluate the reliability of ultrasonographic measures of the acromiohumeral distance (AHD) in shoulder positions linked to wheelchair propulsion in manual wheelchair users (MWUs) with spinal cord injury (SCI) and able-bodied individuals; (2) to compare ultrasonographic measures of AHD, supraspinatus tendon thickness, and occupation ratio between MWUs with SCI with and without shoulder pain (rotator cuff [RC] tendinopathy); and (3) to compare these ultrasonographic measures between MWUs with SCI and able-bodied individuals.
Design: Cross-sectional study.
Setting: Rehabilitation centers.
Participants: Three groups of participants (N=95; aged between 18 and 60y) were recruited within a convenience sample: objective 1: 16 MWUs with SCI (mean age, 43±9y; height, 172±13 cm, weight, 84±10 kg) and 16 able-bodied individuals (mean age, 28±9y; height, 176±11 cm, weight, 72±12 kg); objectives 2 and 3: 37 MWUs with SCI (17 with [mean age, 47±11y; height, 172±14 cm, weight, 68±11 kg] and 20 without [mean age, 45±10y; height, 172±15 cm, weight, 84±30 kg] RC tendinopathy) and 26 able-bodied individuals (mean age, 31±5y; height, 175±12 cm; weight, 89±14 kg).
Interventions: Not applicable.
Main outcome measures: AHD, supraspinatus tendon thickness, and occupation ratio of the supraspinatus tendon measured using ultrasound imaging systems.
Results: (1) Excellent intra- and interrater reliability of AHD was obtained in each arm position (intraclass correlation coefficient>.85); (2) MWUs without shoulder pain have thicker tendon than do MWUs with RC tendinopathy; and (3) a significant Group × Position interaction was found for AHD measures when comparing MWUs with SCI with able-bodied individuals (greater AHD at the end of the push phase for MWUs with SCI). A thicker tendon and a higher occupation ratio were also found in MWUs with SCI than in able-bodied individuals.
Conclusions: Ultrasonography is a reliable technology to evaluate AHD in MWUs in shoulder positions linked to wheelchair propulsion. Supraspinatus tendon thickness and occupation ratio of AHD adequately discriminate between MWUs with SCI and able-bodied individuals. This shows that these ultrasonographic measures can be used in future studies of populations with SCI to better understand the changes at the shoulder joint in MWUs.
Keywords: Pain; Rehabilitation; Rotator cuff; Shoulder; Spinal cord injuries; Ultrasonography; Wheelchairs.
Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Ultrasound measures of supraspinatus tendon thickness and acromiohumeral distance in rotator cuff tendinopathy are reliable.J Clin Ultrasound. 2016 Mar-Apr;44(3):159-66. doi: 10.1002/jcu.22318. Epub 2015 Dec 15. J Clin Ultrasound. 2016. PMID: 26666736
-
Ultrasonographic measurement of the acromiohumeral distance in spinal cord injury: Reliability and effects of shoulder positioning.J Spinal Cord Med. 2015 Nov;38(6):700-8. doi: 10.1179/2045772314Y.0000000205. Epub 2014 Jun 26. J Spinal Cord Med. 2015. PMID: 24968117 Free PMC article.
-
Transfer Technique Is Associated With Shoulder Pain and Pathology in People With Spinal Cord Injury: A Cross-Sectional Investigation.Arch Phys Med Rehabil. 2016 Oct;97(10):1770-6. doi: 10.1016/j.apmr.2016.03.026. Epub 2016 Apr 23. Arch Phys Med Rehabil. 2016. PMID: 27117384
-
Effectiveness of Exercise Programs for Management of Shoulder Pain in Manual Wheelchair Users With Spinal Cord Injury.J Neurol Phys Ther. 2015 Oct;39(4):197-203. doi: 10.1097/NPT.0000000000000103. J Neurol Phys Ther. 2015. PMID: 26308939 Review.
-
Exploring the biomechanical link between wheelchair propulsion, shoulder injury and shoulder pain: A scoping review.J Biomech. 2025 May;185:112678. doi: 10.1016/j.jbiomech.2025.112678. Epub 2025 Apr 10. J Biomech. 2025. PMID: 40250244
Cited by
-
Comparison of glenohumeral joint kinematics between manual wheelchair tasks and implications on the subacromial space: A biplane fluoroscopy study.J Electromyogr Kinesiol. 2022 Feb;62:102350. doi: 10.1016/j.jelekin.2019.08.004. Epub 2019 Aug 23. J Electromyogr Kinesiol. 2022. PMID: 31481296 Free PMC article.
-
Shoulder mechanical impingement risk associated with manual wheelchair tasks in individuals with spinal cord injury.Clin Biomech (Bristol). 2020 Jan;71:221-229. doi: 10.1016/j.clinbiomech.2019.10.017. Epub 2019 Oct 20. Clin Biomech (Bristol). 2020. PMID: 32035338 Free PMC article.
-
Effect of Fatiguing Wheelchair Propulsion and Weight Relief Lifts on Subacromial Space in Wheelchair Users.Front Rehabil Sci. 2022 Apr 27;3:849629. doi: 10.3389/fresc.2022.849629. eCollection 2022. Front Rehabil Sci. 2022. PMID: 36189050 Free PMC article.
-
Changes to Biceps and Supraspinatus Tendons in Response to a Progressive Maximal Treadmill-Based Propulsion Aerobic Fitness Test in Manual Wheelchair Users: A Quantitative Musculoskeletal Ultrasound Study.Rehabil Res Pract. 2021 Mar 1;2021:6663575. doi: 10.1155/2021/6663575. eCollection 2021. Rehabil Res Pract. 2021. PMID: 33747566 Free PMC article.
-
Models of care for musculoskeletal shoulder pain in spinal cord injury: A scoping review.J Spinal Cord Med. 2024 May;47(3):327-344. doi: 10.1080/10790268.2023.2183335. Epub 2023 Mar 13. J Spinal Cord Med. 2024. PMID: 36913538 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical