. 2016 May:21:133-9.
doi: 10.1016/j.sleep.2015.12.013. Epub 2016 Feb 1.

Identifying obstructive sleep apnea after stroke/TIA: evaluating four simple screening tools

Affiliations

Identifying obstructive sleep apnea after stroke/TIA: evaluating four simple screening tools

Mark I Boulos et al. Sleep Med. 2016 May.

Abstract

Objective: Despite its high prevalence and unfavorable clinical consequences, obstructive sleep apnea (OSA) often remains underappreciated after cerebrovascular events. The purpose of our study was to evaluate the clinical utility of four simple paper-based screening tools for excluding OSA after stroke or transient ischemic attack (TIA).

Patients/methods: Sixty-nine inpatients and outpatients with stroke or TIA during the past 180 days completed the 4-Variable screening tool (4V), STOP-BAG questionnaire (ie, STOP-BANG questionnaire without the neck circumference measurement), Berlin questionnaire, and the Sleep Obstructive apnea score optimized for Stroke (SOS). They subsequently underwent objective testing using a portable sleep monitoring device. Cutoffs were selected to maximize sensitivity and exclude OSA (AHI ≥ 10) in ≥10% of the cohort.

Results: The mean age was 68.3 ± 14.2 years and 47.8% were male. Thirty-two patients (46.4%) were found to have OSA. Male sex, body mass index (BMI), and atrial fibrillation were independent predictors of OSA. Among the screening tools, the 4V had the greatest area under the curve (AUC) of 0.688 (p = 0.007); the sensitivity was 96.9% for a cutoff of <6. The STOP-BAG also significantly detected OSA with an AUC of 0.677 (p = 0.012); the sensitivity was 93.8% for a cutoff of <2. Scores on the 4V and STOP-BAG were significantly correlated with the AHI.

Conclusions: The 4V and STOP-BAG questionnaire may aid clinicians with ruling out OSA within 180 days of stroke/TIA. Due to the atypical presentation of poststroke/TIA OSA, these tools are only moderately predictive; objective testing should still be used for OSA diagnosis in this population.

Keywords: 4-Variable screening tool; Berlin questionnaire; Obstructive sleep apnea; STOP-BANG questionnaire; Sleep Obstructive apnea score optimized for Stroke; Stroke; Transient ischemic attack.