Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2016 Dec;30(6):658-661.
doi: 10.1080/02688697.2016.1206179. Epub 2016 Jul 25.

O-arm with navigation versus C-arm: a review of screw placement over 3 years at a major trauma center

Affiliations
Comparative Study

O-arm with navigation versus C-arm: a review of screw placement over 3 years at a major trauma center

S K Verma et al. Br J Neurosurg. 2016 Dec.

Abstract

Introduction: There is a relatively high incidence of screw misplacement during spinal instrumentation due to distortion of normal anatomy following spinal trauma. The O-arm is the next-generation spinal navigation tool that provides intraoperative 3-D imaging and navigation for spine surgeries.

Aims and objectives: To evaluate and compare the use of O-arm as compared to C-arm for spinal trauma in a Level I trauma center in India.

Materials and methods: In this retrospective study over 3 years (July 2010-April 2013), All patients of spinal injury who underwent spinal instrumentation were divided into O-arm group and C-arm group. Accuracy of screw placement was assessed during each surgery in both groups.

Results: A total of 587 patients were evaluated during the study period. There were 278 patients in O-arm group and 309 patients in C-arm group. Both groups were well matched in mean age (27.7 vs. 28.9 years), ASIA grades, and level of injury. The number of screws placed was significantly higher in the C-arm group as compared to the O-arm group (2173 vs. 1720). However, the O-arm group had significantly less screw malplacement rate of 0.93% (n = 16) as compared to malplacement rate in C-arm group of 8.79% (n = 191, p < 0.05).

Conclusion: Use of O-arm imaging system ensures accurate screw placement and dramatically decreases screw malplacement rate, thus providing better patient safety. Its use is especially beneficial in academic and teaching centers where novice surgeons can attain results equivalent to that of experts in spinal instrumentation.

Keywords: O-arm; complication; instrumentation; pedicle screw; spinal injury.