The effect of blood perfusion rate on the temperature distributions induced by multiple, scanned and focused ultrasonic beams in dogs' kidneys in vivo
- PMID: 2746052
- DOI: 10.3109/02656738909140473
The effect of blood perfusion rate on the temperature distributions induced by multiple, scanned and focused ultrasonic beams in dogs' kidneys in vivo
Abstract
The effect of blood perfusion rate on the temperature distribution during scanned, focused ultrasound hyperthermia was investigated using an in vivo dog kidney model. The results showed that the ultrasound beams could penetrate through the body wall without severe distortion, and that they could be used to induce controlled temperature elevations in the target volume. The blood perfusion rate of the heated tissue significantly modified the temperature distribution and the temperatures achieved in the kidney with no flow were about five times higher than in the case with full flow for the same applied acoustic power. It was also demonstrated that the power deposition pattern produced by scanned focused ultrasonic fields could be modified to give an acceptable temperature distribution in different perfusion situations. Similar trends were also obtained by using the bioheat transfer equation to simulate the experiment. Both the magnitude of the temperature elevations and the effect of perfusion on the temperature distributions obtained in the experiments were in agreement with the simulations. The main difference occurred at high perfusion rates where the experiments showed significant temperature elevation outside of the scanned volume and the simulation results predicted hardly any temperature increase 5 mm outside the scan. These observations indicate that both the theoretical power calculation programme and the temperature simulations will have value in the design of optimal heating systems, treatment planning and in the retrospective of the achieved temperature distributions.
Similar articles
-
A scanned, focused, multiple transducer ultrasonic system for localized hyperthermia treatments. 1987.Int J Hyperthermia. 2010 Feb;26(1):1-11. doi: 10.3109/02656730903492916. Int J Hyperthermia. 2010. PMID: 20100046
-
Hot spots created at skin-air interfaces during ultrasound hyperthermia.Int J Hyperthermia. 1990 Nov-Dec;6(6):1005-12. doi: 10.3109/02656739009140983. Int J Hyperthermia. 1990. PMID: 2286789
-
A scanned, focused, multiple transducer ultrasonic system for localized hyperthermia treatments.Int J Hyperthermia. 1987 Jan-Feb;3(1):21-35. doi: 10.3109/02656738709140370. Int J Hyperthermia. 1987. PMID: 3559296
-
Flow dependence of 2-D temperature distributions induced in the perfused canine kidney by ultrasound.Int J Hyperthermia. 1991 Mar-Apr;7(2):367-83. doi: 10.3109/02656739109005002. Int J Hyperthermia. 1991. PMID: 1880461
-
Theoretical and experimental evaluation of a temperature controller for scanned focused ultrasound hyperthermia.Med Phys. 1990 Jul-Aug;17(4):615-25. doi: 10.1118/1.596581. Med Phys. 1990. PMID: 2215406
Cited by
-
Focused Ultrasound Hyperthermia Mediated Drug Delivery Using Thermosensitive Liposomes and Visualized With in vivo Two-Photon Microscopy.Theranostics. 2017 Jul 7;7(10):2718-2731. doi: 10.7150/thno.19662. eCollection 2017. Theranostics. 2017. PMID: 28819458 Free PMC article.
-
Thermal strain imaging: a review.Interface Focus. 2011 Aug 6;1(4):649-64. doi: 10.1098/rsfs.2011.0010. Epub 2011 May 23. Interface Focus. 2011. PMID: 22866235 Free PMC article.
-
In vivo monitoring of focused ultrasound surgery using local harmonic motion.Ultrasound Med Biol. 2009 Jan;35(1):65-78. doi: 10.1016/j.ultrasmedbio.2008.07.001. Epub 2008 Sep 21. Ultrasound Med Biol. 2009. PMID: 18805626 Free PMC article.
-
In Silico Approach to Model Heat Distribution of Magnetic Hyperthermia in the Tumoral and Healthy Vascular Network Using Tumor-on-a-Chip to Evaluate Effective Therapy.Pharmaceutics. 2024 Aug 31;16(9):1156. doi: 10.3390/pharmaceutics16091156. Pharmaceutics. 2024. PMID: 39339193 Free PMC article.
-
Modeling the thermo-acoustic effects of thermal-dependent speed of sound and acoustic absorption of biological tissues during focused ultrasound hyperthermia.J Med Ultrason (2001). 2015 Oct;42(4):489-98. doi: 10.1007/s10396-015-0643-3. Epub 2015 Jun 13. J Med Ultrason (2001). 2015. PMID: 26576973
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources