Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 Oct;66(5):321-6.
doi: 10.1007/s13224-015-0678-9. Epub 2015 Mar 15.

Pregnancy Outcome in Women with Mechanical Prosthetic Heart Valves Treated with Unfractionated Heparin (UFH) or Enoxaparin

Affiliations

Pregnancy Outcome in Women with Mechanical Prosthetic Heart Valves Treated with Unfractionated Heparin (UFH) or Enoxaparin

Khalid Abd Aziz Mohamad Khader et al. J Obstet Gynaecol India. 2016 Oct.

Abstract

Objective: This study was carried out to determine the maternal (including thromboembolic and hemorrhagic complications) and fetal outcomes (including miscarriage, stillbirth, baby death, and live birth) in women with mechanical heart valves managed with therapeutic doses of unfractionated heparin (UFH) versus enoxaparin during pregnancy.

Methods: This is a prospective comparative, nonrandomized study. Pregnant women with mechanical heart valves presenting to high-risk pregnancy unit of Benha University Hospital, Egypt were treated with UFH 15,000 U/12 h versus enoxaparin (Clexane) 1 mg/kg SC/12 h during pregnancy and the results were analyzed.

Results: 40 pregnant women were included in the study. In 20 pregnant women, anticoagulation was with UFH, and 20 pregnant women received enoxaparin. One (3 %) thrombotic complication occurred with enoxaparin treatment. Noncompliance or subtherapeutic levels contributed to this outcome in this case. Antenatal hemorrhage occurred in 4 (10 %) and postpartum hemorrhagic complications in 5 (12.5 %) pregnancies. Of the 32 pregnant women who continued after 20 weeks' gestation, 100 % (17/17) of the women taking predominantly UFH had a surviving infant compared with 93 % (14/15) of the women taking primarily enoxaparin (p = 0.25). One intrauterine fetal death occurred in the enoxaparin group. There was no significant difference in the live birth rates between the two groups (p = 0.31).

Conclusions: Compliance with therapeutic dose of UFH during pregnancy in women with mechanical heart valves is associated with a low risk of valve thrombosis and good fetal outcomes, but meticulous monitoring is essential.

Keywords: Enoxaparin; Pregnancy; Prosthetic heart valves; Thromboembolism; UFH.

PubMed Disclaimer

Figures

Fig. 1
Fig. 1
Flow chart of pregnant women in the study

References

    1. Elkayam U, Bitar F. Valvular heart disease and pregnancy: part II: prosthetic valves. J Am Coll Cardiol. 2005;46:403–410. doi: 10.1016/j.jacc.2005.02.087. - DOI - PubMed
    1. Chan WS, Anand S, Ginsberg JS. Anticoagulation of pregnant women with mechanical heart valves: a systematic review of the literature. Arch Intern Med. 2000;160:191–196. doi: 10.1001/archinte.160.2.191. - DOI - PubMed
    1. Ginsberg JS, Barron WM. Pregnancy and prosthetic heart valves. Lancet. 1994;344:1170–1172. doi: 10.1016/S0140-6736(94)90501-0. - DOI - PubMed
    1. Hall JG, Pauli RM, Wilson KM. Maternal and fetal sequelae of anticoagulation during pregnancy. Am J Med. 1980;68:122–140. doi: 10.1016/0002-9343(80)90181-3. - DOI - PubMed
    1. Briggs GB, Bodendorfer JW, Freeman RK, et al., editors. Drugs in pregnancy and lactation. Baltimore: Williams and Wilkins; 1994.

LinkOut - more resources