Randomized Controlled Trial
. 2016 Dec;21(6):345-351.
doi: 10.1097/MBP.0000000000000208.

Blood pressure cuff comparability study

Affiliations
Randomized Controlled Trial

Blood pressure cuff comparability study

Yechiam Ostchega et al. Blood Press Monit. 2016 Dec.

Abstract

Background: Manufacturer-supplied blood pressure (BP) cuffs are part of the automatic oscillometric BP devices algorithm.

Materials and methods: This study assessed the differences in BP values using the Omron HEM 907-XL (Omron) device with two types of cuffs: the Baum cuff (BC) and the supplied Omron cuff (OC). A sample of 102 adults participated in the study, 34 per cuff size (adult, large, and extra-large). After a 5-min resting period, three pairs of BP determinations (systolic and diastolic) were taken simultaneously on both arms. One arm was cuffed with a BC and the other arm was cuffed with an OC. The cuffs were switched to opposite arms after 5 min of rest. The order was decided randomly as to which cuff was applied to which arm first.

Results: The BP readings were highly correlated between the cuffs (systolic BP, r=0.98; diastolic BP, r=0.98). The overall mean differences (BC-OC) were 2.66 mmHg (SD=3.9 mmHg) for systolic BP (P<0.05) and 0.33 mmHg (SD=2.03 mmHg) for diastolic BP (P>0.05). Increased cuff size corresponded to increased differences in systolic BP values (adult: 1.51 mmHg; large: 2.56 mmHg; and extra-large: 3.9 mmHg; P<0.05). For diastolic BP values, a statistically significant difference was observed only for adult cuff size (difference=1.31 mmHg, SD=1.34 mmHg, P<0.05).

Conclusion: Using a BC with the Omron could result in higher systolic BP readings and higher diastolic BP readings with the adult cuff size.

PubMed Disclaimer

Conflict of interest statement

Conflicts of interest

There are no conflicts of interest.

Figures

Fig. 1
Fig. 1
Between cuffs correlation scatter plot overlaid with an identity line and a regression line (systolic). BP, blood pressure.
Fig. 2
Fig. 2
Between cuffs correlation scatter plot overlaid with an identity line and a regression line (diastolic). BP, blood pressure.
Fig. 3
Fig. 3
Bland–Altman graph Bauman versus Omron cuffs (systolic). BP, blood pressure.
Fig. 4
Fig. 4
Bland–Altman graph Bauman versus Omron cuffs (diastolic). BP, blood pressure.

References

    1. Ostchega Y, Zhang G, Sorlie P, Hughes JP, Reed-Gillette DS, Nwankwo T, Yoon S. Blood pressure randomized methodology study comparing automatic oscillometric and mercury sphygmomanometer devices: National Health and Nutrition Examination Survey, 2009–2010. Hyattsville, MD: National Center for Health Statistics; 2012. - PubMed
    1. Alpert BS, Quinn D, Gallick D. Oscillometric blood pressure: a review for clinicians. J Am Soc Hypertens 2014; 8:930–938. - PubMed
    1. Shaw KC, McEniery CM, Wilkinson IB, Brown MJ. Unsafe health and safety: sphygmomanometer cuffs are not interchangeable. J Hum Hypertens 2013; 27:434–436. - PubMed
    1. Cassidy P, Jones K. A study of inter-arm blood pressure differences in primary care. J Hum Hypertens 2001; 15:519–522. - PubMed
    1. Eguchi K, Yacoub M, Jhalani J, Gerin W, Schwartz JE, Pickering TG. Consistency of blood pressure differences between the left and right arms. Arch Intern Med 2007; 167:388–393. - PubMed

Publication types