Total shoulder replacement using a bone ingrowth central peg polyethylene glenoid component: a prospective clinical and computed tomography study with short- to mid-term follow-up
- PMID: 27506572
- DOI: 10.1007/s00264-016-3255-7
Total shoulder replacement using a bone ingrowth central peg polyethylene glenoid component: a prospective clinical and computed tomography study with short- to mid-term follow-up
Abstract
Aim of the study: To assess the clinical and computed tomography (CT) outcomes of shoulder replacement with a novel bone ingrowth all-polyethylene glenoid component (APGC).
Methods: Twenty-eight patients (30 shoulders) with osteoarthritis, mean age 62.3 years (range, 45-75), were implanted with the novel component between 2011 and 2013. Patients were evaluated by active range of motion (ROM), Constant-Murley score (CMS), simple shoulder test (SST), X-rays, and multidetector CT at two months and at a mean follow-up of 31 months (range, 24-39). Early and late follow-up CT scans were available for 21/30 shoulders.
Results: Median ROM increased from 105 to 160° for anterior elevation, from 100 to 160° for lateral elevation, from 20 to 40° for external rotation, and from 2 to 10 points for internal rotation (all p < 0.001). CMS rose from 30 to 80.5 points and SST from 2.5 to 11 (both p < 0.0001). None of the glenoid components migrated. Progressive radiolucency was seen in 28/30 shoulders. There was a strong correlation between greater bone ingrowth (median Arnold score: 7) and lower radiolucency score (median Yian score: 2) at the last follow-up (p < 0.001). Osteolysis around the central peg was seen in two shoulders. There was no correlation between clinical scores and CT findings (p >0.05).
Discussion: The partially cemented glenoid component for TSR assessed in this study resulted in satisfactory shoulder function at an early follow-up. The glenoid prosthesis was stable, with few radiolucent lines and good central peg bone ingrowth.
Conclusions: The satisfactory bone ingrowth documented on CT is encouraging and supports the use of the new prosthesis. Long-term follow-up studies can confirm if this device represents a rational alternative to fully cemented polyethylene glenoids.
Keywords: Arthroplasty; Bone ingrowth; Glenoid component; Shoulder.
Similar articles
-
Clinical and Radiographic Results of an All-Polyethylene Pegged Bone-Ingrowth Glenoid Component.J Bone Joint Surg Am. 2016 Jul 6;98(13):1090-6. doi: 10.2106/JBJS.15.00475. J Bone Joint Surg Am. 2016. PMID: 27385682
-
Clinical and radiographic outcomes of an all-polyethylene fluted central peg glenoid component, implanted utilizing an off-label, uncemented technique, at a minimum 5-year follow-up.J Shoulder Elbow Surg. 2020 Nov;29(11):2292-2298. doi: 10.1016/j.jse.2020.02.027. Epub 2020 Jun 1. J Shoulder Elbow Surg. 2020. PMID: 32499196
-
Radiographic and clinical outcomes of total shoulder arthroplasty with an all-polyethylene pegged bone ingrowth glenoid component: prospective short- to medium-term follow-up.J Shoulder Elbow Surg. 2016 Feb;25(2):246-55. doi: 10.1016/j.jse.2015.07.008. Epub 2015 Sep 28. J Shoulder Elbow Surg. 2016. PMID: 26422526
-
Total shoulder arthroplasty with hybrid fixation of glenoid components consisting of cementless porous metal pegs or cage along with cemented backside polyethylene surface: a systematic review.Musculoskelet Surg. 2020 Dec;104(3):229-236. doi: 10.1007/s12306-020-00670-y. Epub 2020 Jun 11. Musculoskelet Surg. 2020. PMID: 32529404
-
Loosening and revision rates after total shoulder arthroplasty: a systematic review of cemented all-polyethylene glenoid and three modern designs of metal-backed glenoid.BMC Musculoskelet Disord. 2020 Feb 21;21(1):114. doi: 10.1186/s12891-020-3135-6. BMC Musculoskelet Disord. 2020. PMID: 32085766 Free PMC article.
Cited by
-
One and two-year clinical outcomes for a polyethylene glenoid with a fluted peg: one thousand two hundred seventy individual patients from eleven centers.Int Orthop. 2019 Feb;43(2):367-378. doi: 10.1007/s00264-018-4213-3. Epub 2018 Dec 3. Int Orthop. 2019. PMID: 30511283
-
Humeral stem lucencies correlate with clinical outcomes in anatomic total shoulder arthroplasty.JSES Int. 2020 May 29;4(3):669-674. doi: 10.1016/j.jseint.2020.03.011. eCollection 2020 Sep. JSES Int. 2020. PMID: 32939504 Free PMC article.
-
Glenoid Prosthesis Design Considerations in Anatomic Total Shoulder Arthroplasty.J Shoulder Elb Arthroplast. 2022 Dec 8;6:24715492221142856. doi: 10.1177/24715492221142856. eCollection 2022. J Shoulder Elb Arthroplast. 2022. PMID: 36518368 Free PMC article. Review.
-
Assessment of anatomical and reverse total shoulder arthroplasty with the scapula-weighted Constant-Murley score.Int Orthop. 2019 Mar;43(3):659-667. doi: 10.1007/s00264-018-4088-3. Epub 2018 Aug 10. Int Orthop. 2019. PMID: 30097729
-
Clinical and radiographic outcomes of total shoulder arthroplasty with a partially cemented all-polyethylene pegged bone-ingrowth glenoid component: a systematic review.Shoulder Elbow. 2021 Oct;13(6):627-641. doi: 10.1177/1758573220944168. Epub 2020 Jul 27. Shoulder Elbow. 2021. PMID: 34804212 Free PMC article.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials