Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2017 Dec;24(6):1912-1921.
doi: 10.1007/s12350-016-0628-7. Epub 2016 Aug 9.

The radiation dose to overweighted patients undergoing myocardial perfusion SPECT can be significantly reduced: validation of a linear weight-adjusted activity administration protocol

Affiliations
Free article

The radiation dose to overweighted patients undergoing myocardial perfusion SPECT can be significantly reduced: validation of a linear weight-adjusted activity administration protocol

Jenny Oddstig et al. J Nucl Cardiol. 2017 Dec.
Free article

Abstract

Background: Large body size can cause a higher proportion of emitted photons being attenuated within the patient. Therefore, clinical myocardial perfusion SPECT (MPS) protocols often include unproportionally higher radioisotope activity to obese patients. The aim was to evaluate if a linear weight-adjusted low-dose protocol can be applied to obese patients and thereby decrease radiation exposure.

Methods and result: Two hundred patients (>110 kg, BMI 18-41, [n = 69], ≤ 110 kg, BMI 31-58, [n = 131]) underwent 99mTc-tetrofosmin stress examination on a Cadmium Zinc Telluride or a conventional gamma camera using new generations of reconstruction algorithm (Resolution Recovery). Patients <110 kg were administered 2.5 MBq/kg, patients between 110 and 120 kg received 430 MBq and patients >120 kg received 570 MBq according to clinical routine. Patients >110 kg had 130% total number of counts in the images compared to patients <110 kg. Recalculating the counts to correspond to an administered activity of 2.5 MBq/kg resulted in similar number of counts across the groups. Image analyses in a subgroup with images corresponding to high activity and 2.5 MBq/kg showed no difference in image quality or ischemia quantification.

Conclusion: Linear low-dose weight-adjusted protocol of 2.5 MBq/kg in MPS can be applied over a large weight span without loss of counts or image quality, resulting in a significant reduction in radiation exposure to obese patients.

Keywords: CZT detector; Myocardial perfusion imaging: SPECT; conventional gamma camera; image quality; radiation dose.

PubMed Disclaimer

Comment in

References

    1. J Nucl Med Technol. 2008 Sep;36(3):155-61 - PubMed
    1. J Nucl Cardiol. 2016 Feb;23 (1):11-20 - PubMed
    1. Circulation. 1998 Feb 17;97(6):535-43 - PubMed
    1. Circulation. 2002 Jan 29;105(4):539-42 - PubMed
    1. Ann ICRP. 2008;38(1-2):1-197 - PubMed

Publication types

Substances

LinkOut - more resources