[Errors in the determination of oxygen consumption using the analysis of respiratory gases]
- PMID: 2751794
[Errors in the determination of oxygen consumption using the analysis of respiratory gases]
Abstract
Analytical investigation of errors showed that the noninvasive determination of oxygen consumption (VO2) from the analysis of respiratory gases fails in giving as reliable results as expected in view of the small measuring uncertainties of internationally available analyzers. Absolute errors of delta FO2 = +/- 0.002 for oxygen fractions and delta FCO2 = +/- 0.001 for carbon dioxide fractions already cause the clinically just tolerated error limits of +/- 20% deviation from the true VO2 value to be exceeded under normal conditions. The approximation formula VO2 = VE (FIO2 - FEO2) gives the most reliable results for low inspiratory oxygen fractions (FIO2). It leads, however, systematically rising with FIO2, to an underestimation of VO2. Assuming 0.7 less than or equal to R less than or equal to 0.9 (R = respiratory quotient), the maximum relative error of VO2 can be limited to 21% for air (FIO2 = 0.21) and 30% for FIO2 = 1 by an appropriate correction factor K using the equation VO2 = VE (K.FIO2 - FEO2). For VO2 greater than or equal to 250 ml/min with VE = 10 l/min, K = 1.006 is suggested.
Similar articles
-
[Indirect calorimetry in artificially respirated children. 2. A measuring procedure and its evaluation in a newly developed metabolism-lung model].Infusionsther Klin Ernahr. 1985 Dec;12(6):294-303. Infusionsther Klin Ernahr. 1985. PMID: 3937811 German.
-
Determination of lactate threshold by respiratory gas exchange measures and blood lactate levels during incremental load work.J Manipulative Physiol Ther. 1993 Jun;16(5):312-8. J Manipulative Physiol Ther. 1993. PMID: 8345314
-
Normalization for peak oxygen uptake increases the prognostic power of the ventilatory response to exercise in patients with chronic heart failure.Am Heart J. 2003 Sep;146(3):542-8. doi: 10.1016/S0002-8703(03)00321-1. Am Heart J. 2003. PMID: 12947376
-
Technical and clinical testing of a computerized indirect calorimeter for use in mechanically ventilated neonates.Am J Clin Nutr. 1991 Jul;54(1):30-4. doi: 10.1093/ajcn/54.1.30. Am J Clin Nutr. 1991. PMID: 1905477
-
[Inverse fick's principle in comparison to measurements of oxygen consumption in respiratory gases. Does intrapulmonary oxygen uptake account for differences shown by different system methods?].Anaesthesist. 1994 Oct;43(10):658-66. doi: 10.1007/s001010050106. Anaesthesist. 1994. PMID: 7818047 Clinical Trial. German.
Cited by
-
Classical experiments in whole-body metabolism: closed-circuit respirometry.Eur J Appl Physiol. 2017 Oct;117(10):1929-1937. doi: 10.1007/s00421-017-3681-2. Epub 2017 Jul 26. Eur J Appl Physiol. 2017. PMID: 28748369 Review.