Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 Aug 15;194(4):519-21.
doi: 10.1164/rccm.201604-0852LE.

Survival after Endobronchial Valve Placement for Emphysema: A 10-Year Follow-up Study

Affiliations

Survival after Endobronchial Valve Placement for Emphysema: A 10-Year Follow-up Study

Justin Garner et al. Am J Respir Crit Care Med. .
No abstract available

PubMed Disclaimer

Figures

Figure 1.
Figure 1.
Prolonged transplant-free survival in which atelectasis occurs after bronchoscopic lung volume reduction with endobronchial valves. The upper line shows significantly improved survival in patients (n = 5) in whom radiological atelectasis occurred after endobronchial valve placement occurred compared with the lower line (n = 14), for which atelectasis did not occur (P = 0.017).

Similar articles

Cited by

References

    1. Davey C, Zoumot Z, Jordan S, McNulty WH, Carr DH, Hind MD, Hansell DM, Rubens MB, Banya W, Polkey MI, et al. Bronchoscopic lung volume reduction with endobronchial valves for patients with heterogeneous emphysema and intact interlobar fissures (the BeLieVeR-HIFi study): a randomised controlled trial. Lancet. 2015;386:1066–1073. - PubMed
    1. Klooster K, ten Hacken NHT, Hartman JE, Kerstjens HAM, van Rikxoort EM, Slebos D-J. Endobronchial valves for emphysema without interlobar collateral ventilation. N Engl J Med. 2015;373:2325–2335. - PubMed
    1. Hopkinson NS, Toma TP, Hansell DM, Goldstraw P, Moxham J, Geddes DM, Polkey MI. Effect of bronchoscopic lung volume reduction on dynamic hyperinflation and exercise in emphysema. Am J Respir Crit Care Med. 2005;171:453–460. - PubMed
    1. Toma TP, Hopkinson NS, Hillier J, Hansell DM, Morgan C, Goldstraw PG, Polkey MI, Geddes DM. Bronchoscopic volume reduction with valve implants in patients with severe emphysema. Lancet. 2003;361:931–933. - PubMed
    1. Sciurba FC, Ernst A, Herth FJF, Strange C, Criner GJ, Marquette CH, Kovitz KL, Chiacchierini RP, Goldin J, McLennan G VENT Study Research Group. A randomized study of endobronchial valves for advanced emphysema. N Engl J Med. 2010;363:1233–1244. - PubMed

Publication types