Three new glucose reflectance meters: Diascan, Glucometer II, and Reflolux II
Abstract
More and more frequently, diabetics use portable blood glucose meters to assess their own glycemic control. New meters are constantly being introduced commercially. We evaluated three recently marketed meter/strip systems in terms of accuracy, precision, and the stability of the colors on the test strips. We compared the results from the meters with those from a Beckman Glucose Analyser and calculated the correlation and regression coefficients (Diascan, r = 0.93, y = 0.64x + 41.76; Glucometer II, r = 0.94, y = 0.86x + 2.32; and Reflolux II, r = 0.99, y = 0.99x + 5.15). Both the Diascan and Glucometer II meters tended to underestimate blood glucose whereas Reflolux II gave unbiased measurements throughout the clinical range. Reflolux II was also the most precise of the three. Furthermore, the Reflolux test strips kept their color over 6 days of storage at 4 degrees C, while strips from the other two systems faded. All three meters are compact, simple to calibrate, and convenient. They remain, however, relatively expensive, as do the test strips.
Similar articles
-
An evaluation and comparison of Reflolux II and Glucometer II, two new portable reflectance meters for capillary blood glucose determination.Diabetes Res Clin Pract. 1988 Feb 19;4(3):177-81. doi: 10.1016/s0168-8227(88)80015-9. Diabetes Res Clin Pract. 1988. PMID: 3359917
-
[Delayed evaluation of test strips for blood glucose determination in small reflectometers].Padiatr Padol. 1991;26(4):177-9. Padiatr Padol. 1991. PMID: 1749625 German.
-
Effect of adverse storage conditions on performance of glucometer test strips.Clin Lab Sci. 2005 Fall;18(4):203-9. Clin Lab Sci. 2005. PMID: 16315736
-
Capillary glucose meter accuracy and sources of error in the ambulatory setting.N Z Med J. 2010 Mar 5;123(1310):74-85. N Z Med J. 2010. PMID: 20360781 Review.
-
A Perspective on the Accuracy of Blood Glucose Meters During Pregnancy.Diabetes Care. 2018 Oct;41(10):2053-2058. doi: 10.2337/dc18-0833. Diabetes Care. 2018. PMID: 30237233 Review.
Cited by
-
Occurrence of low blood glucose concentrations during the afternoon in type 2 (non-insulin-dependent) diabetic patients on oral hypoglycaemic agents: importance of blood glucose monitoring.Diabetologia. 1991 Sep;34(9):662-7. doi: 10.1007/BF00400996. Diabetologia. 1991. PMID: 1955099
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources