. 2017 Jul;78(1):193-203.
doi: 10.1002/mrm.26364. Epub 2016 Aug 16.

Prospective head motion correction using FID-guided on-demand image navigators

Affiliations
Free article

Prospective head motion correction using FID-guided on-demand image navigators

Maryna Waszak et al. Magn Reson Med. 2017 Jul.
Free article

Abstract

Purpose: We suggest a motion correction concept that employs free-induction-decay (FID) navigator signals to continuously monitor motion and to guide the acquisition of image navigators for prospective motion correction following motion detection.

Methods: Motion causes out-of-range signal changes in FID time series that, and in this approach, initiate the acquisition of an image navigator. Co-registration of the image navigator to a reference provides rigid-body-motion parameters to facilitate prospective motion correction. Both FID and image navigator are integrated into a prototype magnetization-prepared rapid gradient-echo (MPRAGE) sequence. The performance of the method is investigated using image quality metrics and the consistency of brain volume measurements.

Results: Ten healthy subjects were scanned (a) while performing head movements (nodding, shaking, and moving in z-direction) and (b) to assess the co-registration performance. Mean absolute errors of 0.27 ± 0.38 mm and 0.19 ± 0.24° for translation and rotation parameters were measured. Image quality was qualitatively improved after correction. Significant improvements were observed in automated image quality measures and for most quantitative brain volume computations after correction.

Conclusion: The presented method provides high sensitivity to detect head motion while minimizing the time invested in acquiring navigator images. Limits of this implementation arise from temporal resolution to detect motion, false-positive alarms, and registration accuracy. Magn Reson Med 78:193-203, 2017. © 2016 International Society for Magnetic Resonance in Medicine.

Keywords: FID navigators; MRI; head imaging; image navigators; motion detection; prospective motion correction.