Randomized Controlled Trial
. 2016 Aug 18;375(7):644-54.
doi: 10.1056/NEJMoa1602494.

Closed-Loop Insulin Delivery during Pregnancy in Women with Type 1 Diabetes

Affiliations
Free article
Randomized Controlled Trial

Closed-Loop Insulin Delivery during Pregnancy in Women with Type 1 Diabetes

Zoe A Stewart et al. N Engl J Med. .
Free article

Abstract

Background: In patients with type 1 diabetes who are not pregnant, closed-loop (automated) insulin delivery can provide better glycemic control than sensor-augmented pump therapy, but data are lacking on the efficacy, safety, and feasibility of closed-loop therapy during pregnancy.

Methods: We performed an open-label, randomized, crossover study comparing overnight closed-loop therapy with sensor-augmented pump therapy, followed by a continuation phase in which the closed-loop system was used day and night. Sixteen pregnant women with type 1 diabetes completed 4 weeks of closed-loop pump therapy (intervention) and sensor-augmented pump therapy (control) in random order. During the continuation phase, 14 of the participants used the closed-loop system day and night until delivery. The primary outcome was the percentage of time that overnight glucose levels were within the target range (63 to 140 mg per deciliter [3.5 to 7.8 mmol per liter]).

Results: The percentage of time that overnight glucose levels were in the target range was higher during closed-loop therapy than during control therapy (74.7% vs. 59.5%; absolute difference, 15.2 percentage points; 95% confidence interval, 6.1 to 24.2; P=0.002). The overnight mean glucose level was lower during closed-loop therapy than during control therapy (119 vs. 133 mg per deciliter [6.6 vs. 7.4 mmol per liter], P=0.009). There were no significant differences between closed-loop and control therapy in the percentage of time in which glucose levels were below the target range (1.3% and 1.9%, respectively; P=0.28), in insulin doses, or in adverse-event rates. During the continuation phase (up to 14.6 additional weeks, including antenatal hospitalizations, labor, and delivery), glucose levels were in the target range 68.7% of the time; the mean glucose level was 126 mg per deciliter (7.0 mmol per liter). No episodes of severe hypoglycemia requiring third-party assistance occurred during either phase.

Conclusions: Overnight closed-loop therapy resulted in better glucose control than sensor-augmented pump therapy in pregnant women with type 1 diabetes. Women receiving day-and-night closed-loop therapy maintained glycemic control during a high proportion of the time in a period that encompassed antenatal hospital admission, labor, and delivery. (Funded by the National Institute for Health Research and others; Current Controlled Trials number, ISRCTN71510001.).

PubMed Disclaimer

Similar articles

Cited by

Publication types

Associated data