Effect of a Cerebral Protection Device on Brain Lesions Following Transcatheter Aortic Valve Implantation in Patients With Severe Aortic Stenosis: The CLEAN-TAVI Randomized Clinical Trial
- PMID: 27532914
- DOI: 10.1001/jama.2016.10302
Effect of a Cerebral Protection Device on Brain Lesions Following Transcatheter Aortic Valve Implantation in Patients With Severe Aortic Stenosis: The CLEAN-TAVI Randomized Clinical Trial
Abstract
Importance: Stroke remains a major predictor of mortality after transcatheter aortic valve implantation (TAVI). Cerebral protection devices might reduce brain injury as determined by diffusion-weighted magnetic resonance imaging (DWMRI).
Objective: To determine the effect of a cerebral protection device on the number and volume of cerebral lesions in patients undergoing TAVI.
Design, setting, and participants: Investigator-initiated, single center, blinded, randomized clinical trial in higher-risk patients with severe aortic stenosis undergoing TAVI at the University of Leipzig Heart Center. Brain MRI was performed at baseline, 2 days, and 7 days after TAVI. Between April 2013 and June 2014, patients were randomly assigned to undergo TAVI with a cerebral protection device (filter group) or without a cerebral protection device (control group). The last 1-month follow-up occurred in July 2014.
Interventions: TAVI with or without a cerebral protection device (filter system).
Main outcomes and measures: The primary end point was the numerical difference in new positive postprocedure DWMRI brain lesions at 2 days after TAVI in potentially protected territories. The first hierarchical secondary outcome was the difference in volume of new lesions after TAVI in potentially protected territories.
Results: Among the 100 enrolled patients, mean (SD) age was 80.0 (5.1) years in the filter group (n = 50) and 79.1 (4.1) years in the control group (n = 50), and the mean (SD) procedural risk scores (logistic EuroScores) were 16.4% (10.0%) in the filter group and 14.5% (8.7%) in the control group. For the primary end point, the number of new lesions was lower in the filter group, 4.00 (interquartile range [IQR], 3.00-7.25) vs 10.00 (IQR, 6.75-17.00) in the control group (difference, 5.00 [IQR, 2.00-8.00]; P < .001). For the first hierarchical secondary end point, new lesion volume after TAVI was lower in the filter group (242 mm3 [95% CI, 159-353]) vs in the control group (527 mm3 [95% CI, 364-830]) (difference, 234 mm3 [95% CI, 91-406]; P = .001). Considering adverse events, 1 patient in the control group died prior to the 30-day visit. Life-threatening hemorrhages occurred in 1 patient in the filter group and 1 in the control group. Major vascular complications occurred in 5 patients in the filter group and 6 patients in the control group. One patient in the filter group and 5 in the control group had acute kidney injury, and 3 patients in the filter group had a thoracotomy.
Conclusions and relevance: Among patients with severe aortic stenosis undergoing TAVI, the use of a cerebral protection device reduced the frequency of ischemic cerebral lesions in potentially protected regions. Larger studies are needed to assess the effect of cerebral protection device use on neurological and cognitive function after TAVI and to devise methods that will provide more complete coverage of the brain to prevent new lesions.
Trial registration: clinicaltrials.gov Identifier: NCT01833052.
Comment in
-
Improving Outcomes From Transcatheter Aortic Valve Implantation: Protecting the Brain From the Heart.JAMA. 2016 Aug 9;316(6):587-8. doi: 10.1001/jama.2016.10316. JAMA. 2016. PMID: 27532912 No abstract available.
Similar articles
-
Filter-based cerebral embolic protection with transcatheter aortic valve implantation: the randomised MISTRAL-C trial.EuroIntervention. 2016 Jul 20;12(4):499-507. doi: 10.4244/EIJV12I4A84. EuroIntervention. 2016. PMID: 27436602 Clinical Trial.
-
Silent cerebral injury after transcatheter aortic valve implantation and the preventive role of embolic protection devices: A systematic review and meta-analysis.Int J Cardiol. 2016 Oct 15;221:97-106. doi: 10.1016/j.ijcard.2016.06.143. Epub 2016 Jun 27. Int J Cardiol. 2016. PMID: 27400304
-
Neurologic Complications of Unprotected Transcatheter Aortic Valve Implantation (from the Neuro-TAVI Trial).Am J Cardiol. 2016 Nov 15;118(10):1519-1526. doi: 10.1016/j.amjcard.2016.08.013. Epub 2016 Aug 23. Am J Cardiol. 2016. PMID: 27645761 Clinical Trial.
-
First-in-man experience with a new embolic deflection device in transcatheter aortic valve interventions.EuroIntervention. 2012 May 15;8(1):51-6. doi: 10.4244/EIJV8I1A9. EuroIntervention. 2012. PMID: 22580248
-
Cerebral protection devices during transcatheter aortic valve implantation.Trends Cardiovasc Med. 2018 Aug;28(6):412-418. doi: 10.1016/j.tcm.2018.01.007. Epub 2018 Feb 2. Trends Cardiovasc Med. 2018. PMID: 29428159 Review.
Cited by
-
First-in-Human Use of the Next-generation ProtEmbo Cerebral Embolic Protection System During Transcatheter Aortic Valve-in-valve Implantation.Interv Cardiol. 2021 Feb 2;16(Suppl 1):1-4. doi: 10.15420/icr.2021.S1. eCollection 2021 Apr. Interv Cardiol. 2021. PMID: 33786063 Free PMC article. Review.
-
A series of four transcatheter aortic valve replacement in failed Perceval valves.Ann Cardiothorac Surg. 2020 Jul;9(4):280-288. doi: 10.21037/acs-2020-surd-20. Ann Cardiothorac Surg. 2020. PMID: 32832409 Free PMC article. Review.
-
Site Variability in Cerebral Embolic Protection for Transcatheter Aortic Valve Implantation and Association With Outcomes.Struct Heart. 2023 Jun 26;7(6):100202. doi: 10.1016/j.shj.2023.100202. eCollection 2023 Nov. Struct Heart. 2023. PMID: 38046858 Free PMC article.
-
Development and Application of a Risk Prediction Model for In-Hospital Stroke After Transcatheter Aortic Valve Replacement: A Report From The Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry.Ann Thorac Surg. 2019 Apr;107(4):1097-1103. doi: 10.1016/j.athoracsur.2018.11.013. Epub 2018 Dec 7. Ann Thorac Surg. 2019. PMID: 30529671 Free PMC article.
-
[Advances in stroke after transcatheter aortic valve replacement].Zhejiang Da Xue Xue Bao Yi Xue Ban. 2025 Mar 25;54(2):167-174. doi: 10.3724/zdxbyxb-2024-0414. Zhejiang Da Xue Xue Bao Yi Xue Ban. 2025. PMID: 40231704 Free PMC article. Review. Chinese.
Publication types
MeSH terms
Associated data
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous