The Value of 3D Printing Models of Left Atrial Appendage Using Real-Time 3D Transesophageal Echocardiographic Data in Left Atrial Appendage Occlusion: Applications toward an Era of Truly Personalized Medicine
- PMID: 27537503
- DOI: 10.1159/000447444
The Value of 3D Printing Models of Left Atrial Appendage Using Real-Time 3D Transesophageal Echocardiographic Data in Left Atrial Appendage Occlusion: Applications toward an Era of Truly Personalized Medicine
Abstract
Aims and objectives: The objective of this study was to assess the clinical feasibility of generating 3D printing models of left atrial appendage (LAA) using real-time 3D transesophageal echocardiogram (TEE) data for preoperative reference of LAA occlusion.
Background: Percutaneous LAA occlusion can effectively prevent patients with atrial fibrillation from stroke. However, the anatomical structure of LAA is so complicated that adequate information of its structure is essential for successful LAA occlusion. Emerging 3D printing technology has the demonstrated potential to structure more accurately than conventional imaging modalities by creating tangible patient-specific models. Typically, 3D printing data sets are acquired from CT and MRI, which may involve intravenous contrast, sedation, and ionizing radiation. It has been reported that 3D models of LAA were successfully created by the data acquired from CT. However, 3D printing of the LAA using real-time 3D TEE data has not yet been explored.
Methods: Acquisition of 3D transesophageal echocardiographic data from 8 patients with atrial fibrillation was performed using the Philips EPIQ7 ultrasound system. Raw echocardiographic image data were opened in Philips QLAB and converted to 'Cartesian DICOM' format and imported into Mimics® software to create 3D models of LAA, which were printed using a rubber-like material. The printed 3D models were then used for preoperative reference and procedural simulation in LAA occlusion.
Results: We successfully printed LAAs of 8 patients. Each LAA costs approximately CNY 800-1,000 and the total process takes 16-17 h. Seven of the 8 Watchman devices predicted by preprocedural 2D TEE images were of the same sizes as those placed in the real operation. Interestingly, 3D printing models were highly reflective of the shape and size of LAAs, and all device sizes predicted by the 3D printing model were fully consistent with those placed in the real operation. Also, the 3D printed model could predict operating difficulty and the presence of a peridevice leak.
Conclusions: 3D printing of the LAA using real-time 3D transesophageal echocardiographic data has a perfect and rapid application in LAA occlusion to assist with physician planning and decision making.
© 2016 S. Karger AG, Basel.
Comment in
-
3D Printing for Left Atrial Appendage (LAA) Modeling Based on Transesophageal Echocardiography: A Step Forward in Closure with LAA Devices.Cardiology. 2016;135(4):249-254. doi: 10.1159/000448024. Epub 2016 Aug 19. Cardiology. 2016. PMID: 27537688 No abstract available.
Similar articles
-
The value of the left atrial appendage orifice perimeter of 3D model based on 3D TEE data in the choice of device size of LAmbre™ occluder.Int J Cardiovasc Imaging. 2019 Oct;35(10):1841-1851. doi: 10.1007/s10554-019-01627-4. Epub 2019 May 27. Int J Cardiovasc Imaging. 2019. PMID: 31134413
-
Device Sizing Guided by Echocardiography-Based Three-Dimensional Printing Is Associated with Superior Outcome after Percutaneous Left Atrial Appendage Occlusion.J Am Soc Echocardiogr. 2019 Jun;32(6):708-719.e1. doi: 10.1016/j.echo.2019.02.003. Epub 2019 Apr 2. J Am Soc Echocardiogr. 2019. PMID: 30948144
-
Evaluating the morphology of the left atrial appendage by a transesophageal echocardiographic 3-dimensional printed model.Medicine (Baltimore). 2017 Sep;96(38):e7865. doi: 10.1097/MD.0000000000007865. Medicine (Baltimore). 2017. PMID: 28930824 Free PMC article.
-
Three-Dimensional (3D) Printing for Left Atrial Appendage Occlusion Device Sizing: A Systematic Review and Comparative Analysis.Cureus. 2025 Apr 10;17(4):e82043. doi: 10.7759/cureus.82043. eCollection 2025 Apr. Cureus. 2025. PMID: 40357068 Free PMC article. Review.
-
Left Atrial Appendage Occlusion/Exclusion: Procedural Image Guidance with Transesophageal Echocardiography.J Am Soc Echocardiogr. 2018 Apr;31(4):454-474. doi: 10.1016/j.echo.2017.09.014. Epub 2017 Nov 20. J Am Soc Echocardiogr. 2018. PMID: 29158017 Review.
Cited by
-
Three-Dimensional Echocardiography Derived Printing: A Review of Workflow, Current, and Future Applications.Curr Cardiol Rep. 2023 Jun;25(6):597-605. doi: 10.1007/s11886-023-01882-x. Epub 2023 Apr 22. Curr Cardiol Rep. 2023. PMID: 37086353 Review.
-
Three-dimensional printing in structural heart disease and intervention.Ann Transl Med. 2019 Oct;7(20):579. doi: 10.21037/atm.2019.09.73. Ann Transl Med. 2019. PMID: 31807560 Free PMC article. Review.
-
The value of the left atrial appendage orifice perimeter of 3D model based on 3D TEE data in the choice of device size of LAmbre™ occluder.Int J Cardiovasc Imaging. 2019 Oct;35(10):1841-1851. doi: 10.1007/s10554-019-01627-4. Epub 2019 May 27. Int J Cardiovasc Imaging. 2019. PMID: 31134413
-
Manufacturing Better Outcomes in Cardiovascular Intervention: 3D Printing in Clinical Practice Today.Curr Treat Options Cardiovasc Med. 2018 Oct 25;20(12):95. doi: 10.1007/s11936-018-0692-1. Curr Treat Options Cardiovasc Med. 2018. PMID: 30361896 Review.
-
The Various Applications of 3D Printing in Cardiovascular Diseases.Curr Cardiol Rep. 2018 May 10;20(6):47. doi: 10.1007/s11886-018-0992-9. Curr Cardiol Rep. 2018. PMID: 29749577 Review.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical