Multicenter Study
. 2016 Oct;192(10):714-21.
doi: 10.1007/s00066-016-1028-2. Epub 2016 Aug 18.

Interobserver variability in gross tumor volume delineation for hepatocellular carcinoma : Results of Korean Radiation Oncology Group 1207 study

Affiliations
Multicenter Study

Interobserver variability in gross tumor volume delineation for hepatocellular carcinoma : Results of Korean Radiation Oncology Group 1207 study

Young Suk Kim et al. Strahlenther Onkol. 2016 Oct.

Abstract

Purpose: There has been increasing use of external beam radiotherapy for localized treatment of hepatocellular carcinoma (HCC) with both palliative and curative intent. Quality control of target delineation in primary HCC is essential to deliver adequate doses of radiation to the primary tumor while preserving adjacent healthy organs. We analyzed interobserver variability in gross tumor volume (GTV) delineation for HCC.

Patients and methods: Twelve radiation oncologists specializing in liver malignancy participated in a multi-institutional contouring dummy-run study of nine HCC cases and independently delineated GTV on the same set of provided computed tomography images. Quantitative analysis was performed using an expectation maximization algorithm for simultaneous truth and performance level estimation (STAPLE) with kappa statistics calculating agreement between physicians. To quantify the interobserver variability of GTV delineations, the ratio of the actual delineated volume to the estimated consensus volume (STAPLE), the ratio of the common and encompassing volumes, and the coefficient of variation were calculated.

Results: The median kappa agreement level was 0.71 (range 0.28-0.86). The ratio of the actual delineated volume to the estimated consensus volume ranged from 0.19 to 1.93 (median 0.94) for all cases. The ratio of the common and encompassing volumes ranged from 0.001 to 0.56 (median 0.25). The coefficient of variation for GTV delineation ranged from 8 to 57 % (median 26 %).

Conclusion: The interobserver variability in target delineation of HCC GTV in this study is noteworthy. Multi-institution studies involving radiotherapy for HCC require appropriate quality assurance programs for target delineation.

Keywords: Chemoembolization; Organs at risk; Quality assurance; Radiofrequency ablation; Radiotherapy.

PubMed Disclaimer

References

    1. Strahlenther Onkol. 2011 Jun;187(6):357-66 - PubMed
    1. Med Phys. 2004 Feb;31(2):333-40 - PubMed
    1. Phys Ther. 2005 Mar;85(3):257-68 - PubMed
    1. Pract Radiat Oncol. 2014 Sep-Oct;4(5):316-22 - PubMed
    1. Yonsei Med J. 2009 Oct 31;50(5):601-12 - PubMed

Publication types

LinkOut - more resources