. 1989 Jun;27(6):1201-5.
doi: 10.1128/jcm.27.6.1201-1205.1989.

Evaluation of the Titertek-NF system for identification of gram-negative nonfermentative and oxidase-positive fermentative bacteria

Affiliations

Evaluation of the Titertek-NF system for identification of gram-negative nonfermentative and oxidase-positive fermentative bacteria

P Kämpfer et al. J Clin Microbiol. 1989 Jun.

Abstract

The Titertek-NF (TT-NF) system (Flow Laboratories GmbH, Meckenheim, Federal Republic of Germany) was evaluated for the identification of 1,289 strains of gram-negative, nonfermentative bacteria and some gram-negative, oxidase-positive bacteria. The oxidase test was also performed. Identifications were classified as correct, not identified (two or more taxa possible and identification score of less than 80%; supplementary tests for furthering the identification were not performed), and incorrect. Correct identification results were further subdivided by the correct level of species or biotype identification as greater than or equal to 98% (category a), 90 to 97% (category b), and 80 to 89% (category c). When compared with conventional identification results, the TT-NF system correctly identified 90.3% of strains (1,164 of 1,289 strains), with 72.5% (935 strains) belonging to category a, 14.7% of strains (189 strains) belonging to category b, and 3.1% of strains (40 strains) belonging to category c. Among the remaining strains, 104 (8.1%) were not identified and 14 (1.1%) were misidentified, and the system failed to generate identification results for 7 strains (0.5%). Reactions within the TT-NF system were reproducible, with an estimated probability of erroneous test results of 0.2%.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Antonie Van Leeuwenhoek. 1980;46(3):233-99 - PubMed
    1. J Clin Microbiol. 1978 Sep;8(3):313-9 - PubMed
    1. Acta Pathol Microbiol Immunol Scand B. 1983 Feb;91(1):35-41 - PubMed
    1. Eur J Clin Microbiol. 1984 Aug;3(4):301-5 - PubMed
    1. J Clin Microbiol. 1984 Oct;20(4):730-4 - PubMed

Publication types

MeSH terms

LinkOut - more resources