Performance of cardiac cadmium-zinc-telluride gamma camera imaging in coronary artery disease: a review from the cardiovascular committee of the European Association of Nuclear Medicine (EANM)
- PMID: 27542010
- DOI: 10.1007/s00259-016-3467-5
Performance of cardiac cadmium-zinc-telluride gamma camera imaging in coronary artery disease: a review from the cardiovascular committee of the European Association of Nuclear Medicine (EANM)
Erratum in
-
Erratum to: Performance of cardiac cadmium-zinc-telluride gamma camera imaging in coronary artery disease: a review from the cardiovascular committee of the European Association of Nuclear Medicine (EANM).Eur J Nucl Med Mol Imaging. 2017 Jan;44(1):176. doi: 10.1007/s00259-016-3540-0. Eur J Nucl Med Mol Imaging. 2017. PMID: 27714422 No abstract available.
Abstract
The trade-off between resolution and count sensitivity dominates the performance of standard gamma cameras and dictates the need for relatively high doses of radioactivity of the used radiopharmaceuticals in order to limit image acquisition duration. The introduction of cadmium-zinc-telluride (CZT)-based cameras may overcome some of the limitations against conventional gamma cameras. CZT cameras used for the evaluation of myocardial perfusion have been shown to have a higher count sensitivity compared to conventional single photon emission computed tomography (SPECT) techniques. CZT image quality is further improved by the development of a dedicated three-dimensional iterative reconstruction algorithm, based on maximum likelihood expectation maximization (MLEM), which corrects for the loss in spatial resolution due to line response function of the collimator. All these innovations significantly reduce imaging time and result in a lower patient's radiation exposure compared with standard SPECT. To guide current and possible future users of the CZT technique for myocardial perfusion imaging, the Cardiovascular Committee of the European Association of Nuclear Medicine, starting from the experience of its members, has decided to examine the current literature regarding procedures and clinical data on CZT cameras. The committee hereby aims 1) to identify the main acquisitions protocols; 2) to evaluate the diagnostic and prognostic value of CZT derived myocardial perfusion, and finally 3) to determine the impact of CZT on radiation exposure.
Keywords: CZT camera; Coronary artery disease; Diagnosis; Perfusion; Prognosis.
Similar articles
-
Prognostic value of a faster, low-radiation myocardial perfusion SPECT protocol in a CZT camera.Int J Cardiovasc Imaging. 2017 Dec;33(12):2049-2056. doi: 10.1007/s10554-017-1202-3. Epub 2017 Jun 29. Int J Cardiovasc Imaging. 2017. PMID: 28664482
-
Left Ventricular Function Assessment Using 2 Different Cadmium-Zinc-Telluride Cameras Compared with a γ-Camera with Cardiofocal Collimators: Dynamic Cardiac Phantom Study and Clinical Validation.J Nucl Med. 2016 Sep;57(9):1370-5. doi: 10.2967/jnumed.115.168575. Epub 2016 Apr 28. J Nucl Med. 2016. PMID: 27127220
-
A performance comparison of novel cadmium-zinc-telluride camera and conventional SPECT/CT using anthropomorphic torso phantom and water bags to simulate soft tissue and breast attenuation.Ann Nucl Med. 2015 May;29(4):342-50. doi: 10.1007/s12149-015-0952-z. Epub 2015 Jan 28. Ann Nucl Med. 2015. PMID: 25628019
-
New solid state cadmium-zinc-telluride technology for cardiac single photon emission computed tomographic myocardial perfusion imaging.Expert Rev Med Devices. 2017 Mar;14(3):213-222. doi: 10.1080/17434440.2017.1296763. Epub 2017 Mar 1. Expert Rev Med Devices. 2017. PMID: 28276752 Review.
-
Novel Cadmium Zinc Telluride Devices for Myocardial Perfusion Imaging-Technological Aspects and Clinical Applications.Semin Nucl Med. 2016 Jul;46(4):273-85. doi: 10.1053/j.semnuclmed.2016.01.002. Semin Nucl Med. 2016. PMID: 27237438 Review.
Cited by
-
Clinical Updates in Coronary Artery Disease: A Comprehensive Review.J Clin Med. 2024 Aug 6;13(16):4600. doi: 10.3390/jcm13164600. J Clin Med. 2024. PMID: 39200741 Free PMC article. Review.
-
Phantom-Based Standardization Method for 123I-metaiodobenzylguanidine Heart-to-Mediastinum Ratio Validated by D-SPECT Versus Anger Camera.Ann Nucl Cardiol. 2023;9(1):85-90. doi: 10.17996/anc.23-00003. Epub 2023 Oct 31. Ann Nucl Cardiol. 2023. PMID: 38058581 Free PMC article.
-
First assessment of simultaneous dual isotope (123I/99mTc) cardiac SPECT on two different CZT cameras: A phantom study.J Nucl Cardiol. 2018 Oct;25(5):1692-1704. doi: 10.1007/s12350-017-0841-z. Epub 2017 Mar 8. J Nucl Cardiol. 2018. PMID: 28275896
-
Artificial Intelligence Empowered Nuclear Medicine and Molecular Imaging in Cardiology: A State-of-the-Art Review.Phenomics. 2023 Dec 5;3(6):586-596. doi: 10.1007/s43657-023-00137-7. eCollection 2023 Dec. Phenomics. 2023. PMID: 38223683 Free PMC article. Review.
-
EANM perspectives for CZT SPECT in brain applications.Eur J Nucl Med Mol Imaging. 2024 Oct;51(12):3680-3684. doi: 10.1007/s00259-024-06788-6. Eur J Nucl Med Mol Imaging. 2024. PMID: 38858281 No abstract available.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical